Points can be configured to clear the following for each tool group or any number of tool groups.
- Tool life counter and
- Tool information.
Specify the following for clear the tool life group points.
Point Class
|
ANALOG
|
Type
|
INT
|
Access
|
Read/Write
|
Valid Addresses
|
CLTG<x>, where x is the tool group number and the data value is the end tool group number.
|
Number of Elements
|
1
|
Example 1
IF
|
Address =
|
CLTG1
|
|
Data Value =
|
0 or 1
|
Then
|
Tool Group 1 is cleared from the CNC system data.
|
Example 2
IF
|
Address =
|
CLTG1
|
|
Data Value =
|
20
|
Then
|
Tool Groups 1 through 20 are cleared from the CNC system data.
|