EW_PROTOCOL (-17)
|
Protocol error
Ethernet version only
|
Data from Ethernet Board is incorrect
|
Contact with the service section or the section in charge.
|
EW_SOCKET (-16)
|
Socket error
Ethernet version only
|
|
Investigate CNC power supply, Ethernet cable and I/F board.
|
EW_NODLL (-15)
|
DLL file error
|
There is no DLL file for each CNC series corresponding to specified node.
|
|
EW_BUS (-11)
|
Bus error
HSSB version only
|
A bus error of CNC system occurred.
|
Contact with the service section or the section in charge.
|
EW_SYSTEM2 (-10)
|
System error (2)
HSSB version only
|
A system error of CNC system occurred.
|
Contact with the service section or the section in charge.
|
EW_HSSB (-9)
|
Communication error of HSSB
HSSB version only
|
|
Investigate the serial line or I/F board of HSSB.
|
EW_HANDLE (-8)
|
Handle number error
|
|
Get the library handle number.
|
EW_VERSION (-7)
|
Version mismatch between the CNC/PMC and library
|
The CNC/PMC version does not match that of the library.
|
Replace the library or the CNC/PMC control software.
|
EW_UNEXP (-6)
|
Abnormal library state
|
An unanticipated error occurred.
|
Contact with the section in charge.
|
EW_SYSTEM (-5)
|
System error
HSSB version only
|
A system error of CNC occurred.
|
Contact with the service section or the section in charge.
|
EW_PARITY (-4)
|
Shared RAM parity error
HSSB version only
|
A hardware error occurred.
|
Contact with the service section.
|
EW_MMCSYS (-3)
|
FANUC drivers installation error
HSSB version only
|
|
The drivers required for execution are not installed.
|
EW_RESET (-2)
|
Reset or stop request
|
The RESET or STOP button was pressed.
|
Call the termination function.
|
EW_BUSY (-1)
|
Busy
|
|
Wait until the completion of CNC processing, or retry.
|
EW_OK (0)
|
Normal termination
|
|
|
EW_FUNC (1)
|
Error (function is not executed, or not available)
|
Specific function which must be executed beforehand has not been executed.
Otherwise that function is not available.
|
|
EW_LENGTH (2)
|
Error (data block length error, error of number of data)
|
|
Check and correct the data block length or number of data.
|
EW_NUMBER (3)
|
Error (data number error)
|
|
Check and correct the data number.
|
EW_ATTRIB(4)
|
Error (data attribute error)
|
|
Check and correct the data attribute.
|
EW_DATA (5)
|
Error (data error)
|
|
Check and correct the data.
For the following operations, this code indicates that the specified program cannot be found.
-
Delete specified program
-
Search specified program
-
Start uploading NC program
|
EW_NOOPT (6)
|
Error (no option)
|
There is no corresponding CNC option.
|
|
EW_PROT (7)
|
Error (write protection)
|
Write operation is prohibited.
|
|
EW_OVRFLOW (8)
|
Error (memory overflow)
|
CNC tape memory is overflowed.
|
|
EW_PARAM (9)
|
Error (CNC parameter error)
|
CNC parameter is set incorrectly.
|
|
EW_BUFFER (10)
|
Error (buffer empty/full)
|
The buffer is empty or full.
|
Wait until completion of CNC processing, or retry.
|
EW_PATH (11)
|
Error (path number error)
|
A path number is incorrect.
|
|
EW_MODE (12)
|
Error (CNC mode error)
|
The CNC mode is incorrect.
|
Correct the CNC mode.
|
EW_REJECT (13)
|
Error (CNC execution rejection)
|
The execution at the CNC is rejected.
|
Check the condition of execution.
|
EW_DTSRVR (14)
|
Error (Data server error)
|
Some errors occur at the data server.
|
|
EW_ALARM (15)
|
Error (alarm)
|
The function cannot be executed due to an alarm in CNC.
|
Remove the cause of alarm.
|
EW_STOP (16)
|
Error (stop)
|
CNC status is stop or emergency.
|
|
EW_PASSWD (17)
|
Error (State of data protection)
|