Policies Used to Generate Recommendations

This topic provides a list of policies used by RBI Strategy Mapping groups to generate RBI Recommendations.

If you want to modify the design of a policy, you must be a member of the following Security Groups:

If you want to view a policy, you must be a member of the following Security Groups:

Criteria Used to Generate RBI Recommendations from RBI Analyses

The following table lists the criteria used by RBI Strategy Mapping Groups to determine the Policy that GE Digital APM uses to select the Inspection Strategy. The selected Inspection Strategy is then used to populate the RBI Recommendation. Specifically:

Note: The GE Digital APM RBI Best Practice assumes that you will use the RBI Strategy Mapping Configurations, RBI Strategy Mapping Details , and policy queries that GE Digital provides, and that you will not modify them.

For an RBI Analysis whose Criticality Item Type value is: ... and that is linked to an RBI Degradation Mechanism with the following Degradation Mechanism value: ...this Policy is selected by GE Digital APM: Additional fields that must contain a value for the policy to be selected:

Any value except:

  • Air Cooled Exchanger-Header
  • Air Cooled Exchanger-Tbs
  • Storage Tank Bottom
  • Heat Exchanger-Bundle
  • Any value associated with a pipe
  • Any value associated with a pressure relief device

Note: Values associated with pressure relief devices are not excluded by the associated policy query. Instead, these criticality item types are not valid for an RBI Analysis whose degradation mechanism is Criticality Calculator Internal Corrosion.

Criticality Calculator Internal Corrosion

Appendix_B
  • Estimated Half Life field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • General Corrosion field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • Non-Intrusive Requirement Met field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • Inspection Priority (Unmitigated Risk) field in the associated RBI Degradation Mechanism
  • Criticality item type in the associated policy

Any of the following values:

  • Air Cooled Exchanger-Header
  • Air Cooled Exchanger-Tbs

Criticality Calculator Internal Corrosion

Appendix_D

  • Estimated Half Life field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • General Corrosion field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • Non-Intrusive Requirement Met field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • Inspection Priority (Unmitigated Risk) field in the associated RBI Degradation Mechanism
  • Criticality item type in the associated policy

Any value except:

  • Storage Tank Bottom
  • Heat Exchanger-Bundle
  • Any value associated with a pressure relief device

Note: Values associated with pressure relief devices are not excluded by the associated policy query. Instead, these criticality item types are not valid for an RBI Analysis whose degradation mechanism is Criticality Calculator External Corrosion.

Criticality Calculator External Corrosion

Appendix_E
  • Estimated Half Life field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • General Corrosion field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • Inspection Priority (Unmitigated Risk) field in the associated RBI Degradation Mechanisms
  • Criticality item type in the associated policy

Any value except:

  • Air Cooled Exchanger-Header
  • Air Cooled Exchanger-Tbs
  • Storage Tank Bottom
  • Heat Exchanger-Bundle
  • Any value associated with a pipe
  • Any value associated with a pressure relief device

Note: Values associated with pressure relief devices are not excluded by the associated policy query. Instead, these criticality item types are not valid for an RBI Analysis whose degradation mechanism is Criticality Calculator Internal Corrosion.

Criticality Calculator External Corrosion Appendix_F
  • Insulated field in the associated RBI Analysis
  • Insulation Damage field in the associated Criticality Ext. Corr. Deg. Mech. Eval. record
  • Estimated Half Life field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • Inspection Priority(Unmitigated Risk) field in the associated RBI Degradation Mechanisms
  • Component Type
  • Criticality item type in the associated policy

Any value except:

  • Air Cooled Exchanger-Header
  • Air Cooled Exchanger-Tbs
  • Heat Exchanger-Bundle

Any of the following values:

  • Amine Cracking (ASCC)
  • Carbonate Cracking
  • Caustic Cracking
  • Chloride Stress Corrosion Cracking (CI SCC)
  • Hydrogen Stress Cracking (HSC)- Hydrofluoric Acid
  • Polythionic Acid SCC (PTA)
  • Sulfide Stress Cracking (SSC)
  • Wet H2S Damage (Blistering, SOHIC, SCC)
Appendix_G
  • Estimated Half Life field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • Damage Mechanism field in the associated Criticality Env. Crack. Deg. Mech. Eval. record
  • Damaged At Last Inspection field in the associated Criticality Env. Crack. Deg. Mech. Eval. record
  • Is Entry Possible field in the associated Criticality Env. Crack. Deg. Mech. Eval. record
  • PT or MT Access field in the associated Criticality Env. Crack. Deg. Mech. Eval. record
  • Inspection Priority (Unmitigated Risk) field in the associated RBI Degradation Mechanism.
  • Estimated Half Life field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • Criticality item type in the associated policy

Any of the following values:

  • Amine Cracking (ASCC)
  • Carbonate Cracking
  • Caustic Cracking
  • Chloride Stress
  • Corrosion Cracking (CI SCC)
  • Hydrogen Stress Cracking (HSC)- Hydrofluoric Acid
  • Hydrofluoric Acid
  • Polythionic Acid SCC (PTA)
  • Sulfide Stress Cracking (SSC)
  • Wet H2S (Blistering, SOHIC, SCC)
  • Criticality Calculator
  • Internal Corrosion Criticality Calculator
  • External Corrosion
Heat Exchanger-Bundle Appendix_H
  • Estimated Half Life field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • Inspection Priority (Unmitigated Risk) field in the associated RBI Degradation Mechanism
  • Criticality item type in the associated policy

Any of the following values:

  • Amine Cracking (ASCC)
  • Carbonate Cracking
  • Caustic Cracking Chloride
  • Stress Corrosion Cracking (CI SCC)
  • Hydrogen Stress Cracking (HSC)- Hydrofluoric Acid
  • Hydrofluoric Acid Polythionic Acid SCC (PTA)
  • Sulfide Stress Cracking (SSC)
  • Amine Cracking
  • Criticality Calculator
  • Internal Corrosion Criticality Calculator
  • External Corrosion
Storage Tank Bottom Appendix_I
  • Estimated Half Life field in the associated Criticality Int. Corr. Deg. Mech. Eval. record
  • Inspection Priority (Unmitigated Risk) field in the associated RBI Degradation Mechanism
  • Criticality item type in the associated policy

Any of the following values:

  • Blocked Discharge
  • Blocked Discharge - Admin Control
  • Control Valve Failure (Fail Opposite)
  • Control Valve Failure (Fail Safe)
  • Electrical Power Failure
  • Exchanger Tube Rupture
  • Fire
  • Liquid Overfill
  • Liquid Overfill - Admin Control
  • Loss of Cooling
  • Runaway Reaction
  • Thermal Relief
  • Thermal Relief - Admin Control
  • Tower Pump
  • Failures Leak

Any value associated with a pressure relief device

PRD_Strategies
  • Inspection Priority (Unmitigated Risk) field in the associated RBI Degradation Mechanism
  • Criticality item type in the associated policy
Pipeline

Any of the following values:

  • Criticality Calculator External Corrosion
  • Criticality Calculator Internal Corrosion
Pipeline Inspection Strategy
  • Is CP System field in the associated RBI Analysis
  • Is Pigging Possible field in the associated RBI Analysis
  • Wall Thickness Loss field in the Criticality Int. Corr. Deg. Mech. Eval. record
  • Wall Thickness Loss field in the Criticality Ext. Corr. Deg. Mech. Eval. record
Pipeline

Any of the following values:

  • Amine Cracking (ASCC)
  • Carbonate Cracking
  • Caustic Cracking
  • Chloride Stress Corrosion Cracking (CI SCC)
  • Hydrogen Stress Cracking (HSC)- Hydrofluoric Acid
  • Polythionic Acid SCC (PTA)
  • Sulfide Stress Cracking (SSC)
  • Wet H2S (Blistering, SOHIC, SCC)
Pipeline Cracking Inspection Strategy
  • Inspection Priority (Unmitigated Risk) field in the associated RBI Degradation Mechanism
  • Is Pigging Possible field in the associated RBI Analysis
Pipeline Third Party Damage TPD Inspection Strategy
  • Previous Damage Points field on the associated Third Party Degradation Mechanism Evaluation
  • Inspection Priority field in the associated RBI Degradation Mechanism

Copyright © 2018 General Electric Company. All rights reserved.