PDWatch - Monitoring partial discharges (X7033)
Overcurrent and Feeder Protection
What will I learn from this course?
- Understand the eventual partial discharges during the running of a substation under metal enclosure
 - Control the UHF method so called "off-line" partial discharge detecting
 - Be efficient in the use of the mobile PDWatch device
 - Use the HM software of the PDWatch under normal conditions on real shielded type equipment
 - Improve G S monitoring
 
Topics
Partial discharges
- Insulation defects in the applications under metal enclosures
 - Different types of insulation defects
 - Physical and chemical phenomena due to partial discharges
 - Electromagnetic waves spread in the applications under metal enclosures
 
Means of detecting
- Conventional method
 - UHF method so called "off-line"
 - Portable material and solution
 - UHF type coupling units
 - Process of checking of the
 - Coupling units used as voltage capacitive detectors
 
Capture principles of the PDWatch
- General presentation
 - Use step by step
 - Recording of the data under the C GRE format
 - Recording of the graphic data
 - Data management
 
Use of the "PDWatch manager" software tool
- General presentation
 - Use step by step
 
Practical Works
- Running of the portable solution
 - Presentation on a real size"shielded" equipment
 - Functioning of the portable solution
 - Synchronizing on a real size shield installation
 - Commissioning
 - Simulations and repairing
 - Communications errors
 - State error of the captors
 
Software tool of the PDWatch
- Safety information
 - Scheduling
 - Installation of material
 - Disjunction of material
 - PDWatch architecture
 
| Duration | 
|---|
| 2.5 days | 
| Who should attend? | 
|---|
| Engineers and technicians | 
Learning path
| Prerequisites | X7033 | 
|---|---|
| Fundamentals in electricity and mechanics. Good knowledge of "shielded" solutions | 70% practical 30% theoretical  | 
PDWatch - Monitoring partial discharges (X7033)
Overcurrent and Feeder Protection
What will I learn from this course?
- Understand the eventual partial discharges during the running of a substation under metal enclosure
 - Control the UHF method so called "off-line" partial discharge detecting
 - Be efficient in the use of the mobile PDWatch device
 - Use the HM software of the PDWatch under normal conditions on real shielded type equipment
 - Improve G S monitoring
 
Topics
Partial discharges
- Insulation defects in the applications under metal enclosures
 - Different types of insulation defects
 - Physical and chemical phenomena due to partial discharges
 - Electromagnetic waves spread in the applications under metal enclosures
 
Means of detecting
- Conventional method
 - UHF method so called "off-line"
 - Portable material and solution
 - UHF type coupling units
 - Process of checking of the
 - Coupling units used as voltage capacitive detectors
 
Capture principles of the PDWatch
- General presentation
 - Use step by step
 - Recording of the data under the C GRE format
 - Recording of the graphic data
 - Data management
 
Use of the "PDWatch manager" software tool
- General presentation
 - Use step by step
 
Practical Works
- Running of the portable solution
 - Presentation on a real size"shielded" equipment
 - Functioning of the portable solution
 - Synchronizing on a real size shield installation
 - Commissioning
 - Simulations and repairing
 - Communications errors
 - State error of the captors
 
Software tool of the PDWatch
- Safety information
 - Scheduling
 - Installation of material
 - Disjunction of material
 - PDWatch architecture
 
| Duration | 
|---|
| 2.5 days | 
| Who should attend? | 
|---|
| Engineers and technicians | 
Learning path
| Prerequisites | X7033 | 
|---|---|
| Fundamentals in electricity and mechanics. Good knowledge of "shielded" solutions | 70% practical 30% theoretical  |