RBI Criticality Analysis Records

RBI Criticality Analysis records are used to determine the results of RBI Analyses. This topic provides an alphabetical list and description of the fields that exist for the RBI Criticality Analysis family . The information in the table reflects the baseline state and behavior of these fields. The Criticality Analysis and What-If Analysis table lists common fields shared across several analysis types. Fields that are unique to a specific component type can be viewed by expanding the proper drop-down heading.

The following families are enabled for site filtering, which means that the records in these families can be assigned to a specific site, and will then only be accessible to users who are assigned to the same site and have the appropriate license and family privileges. See the Site Filtering section of the documentation for more information on using this feature.

RBI Criticality Analysis and What-If Analysis

Field

Data Type

Description

Behavior and Usage

Main

Analysis ID

Character

Specifies the Record ID of the Equipment or Functional Location Record.

When you create an analysis through the RBI Workflow, the Meridium Enterprise APM system automatically populates this field.

Analysis Start Date

Date

The date on which the analysis began.

You can use the Calendar feature to select the date on which the analysis began.

This field is required.

Criticality Item Type

Character

Describes the type of component being assessed.

This data will be used to select which elements are required to calculate risk.

Date Criticality Calculated

Date

The date on which the Criticality Analysis was calculated.

You can use the Calendar feature to select the date on which the analysis was calculated.

Effective Date for Risk Analysis

Date

A designated future date at which time the risk data becomes valid.

You can use the Calendar feature to select the date on which you want to access future risk.

Generic Failure Frequency

 Numeric

A Probability of Failure (PoF) developed for specific component types based on a large population of component data that does not include the effects of specific damage mechanisms.

This data is one of the factors used to determine the PoF.

Location ID

Character

Identifies the functional location.

 

Scenario ID

Character

Identifies a particular set of data or activities.

May be used to query data in Meridium Enterprise APM that is all related to a common activity or data set.

Scenario Reference Date

Date

The date on which the scenario occurred.

May be used to query data in Meridium Enterprise APM that is all related to a common activity or data set.

Process Data

Operating Pressure

Numeric

The normal operating pressure for a piece of equipment.

 

Operating Temperature

Numeric

The normal operating temperature for a piece of equipment.

 

Representative Fluid

Character

The fluid that represents or makes up the greatest volume of the asset.

In some cases, the fluid that represents the greatest Cause of Failure (CoF) may be selected. 

Tube Nominal Thickness

Numeric

The manufactured thickness of the tube wall.

 

Tube Operating Press Channel

Numeric

The normal operating pressure for a Tube Bundle.

Required only for an RBI Analysis record whose Criticality Item Type is Heat Exchanger-Bundle.

Tube Operating Temp Channel

Numeric

The normal operating temperature for a Tube Bundle.

 

Tube Rep Fluid Channel

Character

The fluid that represents or makes up the greatest volume of the asset.

In some cases the fluid that represents the greatest Cause of Failure (CoF) may be selected.

Design Data

Allowable Stress

Numeric

The maximum amount of pressure that can a component can safely withstand.

This value in this field, in addition to the following other Piping Stress fields, is used to determine the value that is populated in the Allowable Stress field in the associated RBI Criticality Analysis record:

  • Code Year
  • Construction Code
  • Design Temperature
  • Material Grade
  • Material Spec
  • Stress Lookup Table

Required only for RBI Analysis records:

  • Whose Criticality Item Type is Storage Tank

-and-

  • Whose Allowable Stress is null or 0 (zero)

-and-

  • That are linked to Criticality Int. Corr. Deg. Mech. Eval. records whose Estimated Minimum Thickness Override? check boxes are not selected

Allowable Stress Override

Logical

Identifies whether or not a user can enter his or her own allowable stress value.

 

Area Humidity

Character

A value that based on the humidity of the geographical region in which the asset is operated.

Required only for an RBI Analysis record that is linked to Criticality Ext. Corr. Deg. Mech. Eval. records.

Code Year

Character

The year in which the design code that corresponds to the component was defined.

The value in this field is used to populate the Code Year field in the associated RBI Criticality Analysis record.

This field must contain a value in order for the Meridium APM system to retrieve:

  • The value in the Allowable Stress field in the Piping Stress record from the Piping Stress reference table.
  • Values in the Material Spec list in the Piping Stress record.

Required only for an RBI Analysis record whose Allowable Stress Override check box is cleared and whose Criticality Item Type is not Storage Tank.

Construction Code

Character

The code to which the asset was originally constructed.

Required only for an RBI Analysis record whose Allowable Stress Override check box is not selected.

Course Number

Numeric

Identifies which shell course on an asset is being assessed. The course number will impact how the allowable stressed data is used.

 

Design Pressure

Numeric

Pressure designated by the manufacturer on the nameplate or the U1 Form.

Required only for an RBI Analysis record whose Allowable Stress Override check box is cleared.

Design Temperature

Numeric

Temperature designated by the manufacturer on the nameplate or the U1 Form.

Required only for an RBI Analysis record whose Allowable Stress Override check box is cleared.

Diameter

Numeric

The width of a circular or cylindrical Asset measured in a straight line.

Required only for an RBI Analysis record:

  • Whose Criticality Item Type is Storage Tank

-and-

  • Whose Diameter is null or > 200 (Feet)

-and-

  • That is linked to a Criticality Int. Corr. Deg. Mech. Eval. record whose Estimated Minimum Thickness Override? check box is not selected.

Insulated

Logical

Indicates whether or not an asset is insulated.

Required only for RBI Analysis records that are linked to Criticality Ext. Corr. Deg. Mech. Eval. records.

Insulation Type

Character

Identifies the insulating material.

The value in this field must be stored in the Insulation Type field in one of the Insulation Type records delivered in the Meridium Enterprise APM baseline database

Joint Efficiency

Numeric

Indicates the extent of inspection used to ensure the quality of welds and the type of weld joints used during construction.

This field must contain one of the following values:

  • 0.35
  • 0.4
  • 0.45
  • 0.5
  • 0.55
  • 0.6
  • 0.65
  • 0.7
  • 0.75
  • 0.8
  • 0.85
  • 0.9
  • 0.95
  • 1.0

Material Grade

Character

The material grade of the component.

 

Material Spec

Character

The material specification of the component.

The value in this field is used to populate the Material Spec field in the associated RBI Criticality Analysis record.

This field must contain a value in order for the Meridium APM system to retrieve:

  • The value in the Allowable Stress field in the Piping Stress record from the Piping Stress reference table.
  • Values in the Material Grade list in the Piping Stress record.

Required only for an RBI Analysis record whose Allowable Stress Override check box is cleared.

Nominal Thickness

Numeric

An estimated or measured thickness used as the starting point for thickness based remaining life calculations.

Required only for an RBI Analysis record whose Criticality Item Type is Heat Exchanger-Bundle.

Stress Lookup Table

Character

Identifies the type of asset being assessed so that the proper design codes are used.

Required only for an RBI Analysis record whose Allowable Stress Override check box is cleared.

Susceptible to CUI

Character

Indicates whether or not the component can be affected by Corrosion Under Insulation.

Required only for an RBI Analysis record:

  • Whose Criticality Item Type is not Heat Exchanger-Bundle

-and-

  • Whose Insulated field is set to null

-and-

  • That is associated with a Criticality Calculator External Corrosion record.

Analysis Results

Driving CoF

Character

The highest cause of failure identified on the asset.

 

Driving Inspection Priority (Unmitigated Risk)

Character

The highest Inspection Priority identified on the asset.

The value in this field is used to drive the inspection recommendations on the asset

Driving PoF

Character

The highest Probability of Failure (PoF) identified on the asset.

 

Inspection Priority (Unmitigated Risk) Rolled Up

Numeric

The highest Inspection Priority identified on the asset.

For a multi-component asset, the highest Inspection Priority will be used

Risk Category

Character

 The range of Risk for the asset.