Model 100
Model 100 Description
Model 100 creates product changes when the Grade Change Tag has a value change. The Add Minutes parameter value is added to the Timestamp of the value change to create the Timestamp for the Product Change. The value of the Tag is used to lookup the Product Code using the Product Cross Reference value.
NOTE: The functionality in this model is available only if you have purchased the Product Management Module.
Model 100 Properties
The following Model properties are set up using the Plant Applications Administrator:
Property |
Description |
Maximum Run Time (Seconds) |
optional: Type the number of seconds you want the model to run. The default is 0 (zero), which means the model will not time out. Typically, you will want to limit the run time of the model only if troubleshooting the model (for example, one of the stored procedures is in an infinite loop). |
Model Processing Group |
Used for multithreading. See the Multithreading topic for more information. |
Grade Change Tag |
A value change of this tag is used to trigger a product change to be created. |
Add Minutes (Optional) |
This value added to the Timestamp of the value change time. |