Model 14
Model 14 Description
Model 14 creates production events when the turnup tag has a value change. The event number is created using the properties defined for this model. The format of the event number is MMM YYYY. The MMM is the three-character month of the month previous to the trigger tag time. The YYYY refers to the a one-digit year. For example, if the trigger tag fires on July 23, 2010, the event name would be JUN 2010. The value for this tag should only change once per month and therefore the event number will be unique.
The functionality in this model is available only if you have purchased the Quality Module.
Model 14 Properties
The following model properties are set up using the Plant Applications Administrator:
Property |
Description |
Maximum Run Time (Seconds) |
optional: Type the number of seconds you want the model to run. The default is 0 (zero), which means the model will not time out. Typically, you will want to limit the run time of the model only if troubleshooting the model (for example, one of the stored procedures is in an infinite loop). |
Model Processing Group |
Used for multithreading. See the Multithreading topic for more information. |
Turnup Tag |
A value change of this tag is used to trigger a new production event to be created. |