Upgrading from Plant Applications Version 7.0 SP5 or 8.0 to 8.2
Before you begin
- You must have SQL Server 2016 (64-bit) or later for upgrading Plant Applications Server from earlier Plant Applications versions and existing PlantApplications Database compatibility must be greater than or equal to 130.
- Ensure that you complete the following procedure specific to the Plant Applications Message Bridge:
- Stop the Message Bridge, RabbitMQ, and Erlang services.
- Uninstall the earlier version of the Plant Applications Message Bridge, RabbitMQ, and Erlang.
The Proficy Server Message Bridge service is disabled.
- Delete following directories:
- C:\Program Files (x86)\Proficy\Proficy Server\RabbitMQMessageBridgeService
- C:\Users\{users who installed MessageBridge}\AppData\Roaming\RabbitMQ
- Delete (if any) the RabbitMQ key from the registry:
- HKEY_LOCAL_MACHINE\SOFTWARE\Ericsson\Erlang\ErlSrv\1.1\RabbitMQ
- Run the
PREPDBUpdImpliedSequence.sql
SQL script.- Mount the ISO file for the Plant Applications or load the DVD if you created one from the ISO file on the application server for Plant Applications.
- Execute the
PREPDBUpdImpliedSequence.sql
file on the Plant Applications database where the Plant Applications is installed.This will populate implied sequence as epoch date(with respect to the forecast start date) instead of integer number (starting from 1).
About this task
Note: If upgrading from a version of Plant Applications earlier than 7.0 SP5, contact Support to uninstall Plant Applications components.