Second Quarter of 2020

Release Date: May 8, 2020

This topic provides a list of product changes released for this module on this date.

Table 1. Enhancements and New Features

The following enhancements and new features have been added.

DescriptionTracking ID
You can now create or link a calibration task with more than one Calibration Template, enabling you to define and use multiple templates to perform calibration for the same asset and task combination. To facilitate this enhancement, the following changes have been made:
  • To retrieve the associated Template for a Task, the relationship “Has Templates” is used instead of the field value in the “MI_TASKCALB_CALIB_TEMPL_ID_N” field.
  • Cardinality of the Relationship “Has Templates” has been changed to “Many To Many”.
  • The following two Catalog Queries have been changed to use the relationship instead of field value:
    • Public\Meridium\Modules\Calibration Management\Queries\Manage Calibration Task with Task Assigned Query
    • Public\Meridium\Modules\Calibration Management\Queries\Manage Calibration Task Without Task Assigned Query
US384941
You can now perform pressure calibration using Fluke 729 Automatic Pressure Calibrator.
Note: Fluke 729 Automatic Pressure Calibrator supports both analog and discrete calibration.
US384751
Table 2. Resolved Issues

The following issues, which existed in one or more previous versions, have been resolved.

DescriptionTracking ID
Previously, after you upgraded the APM database from V3 to V4, you could not update the applied templates when you changed the Calibration Strategy in a Calibration Profile. This issue has been resolved.US379741
Previously, after you upgraded the APM database from V3 to V4, certain fields in the Calibration Profile were set to empty. Also, you could not change the Calibration Strategy or link additional assets to the upgraded Calibration Profile. This issue has been resolved.US379739
Previously, when performing automated calibration using a Fluke Calibrator connected to a computer with a culture setting other than English, the task list was not updated in the Fluke Calibrator device. This issue has been resolved.DE131106
Previously, when you create a Calibration Event record using a Functional Test template, with the Response Type as Selection in the template detail record, an error occurred. This issue has been resolved.DE129885
Previously, when you created a Functional Test template, the users associated with the sites other than your default site could not access the records in the Details section of the template. This issue has been resolved.DE127061
Previously, while creating a Calibration Event, if the mandatory fields were blank, an error occurred. This issue has been resolved. DE124768
Previously, when you performed a manual square-root calibration, the RMS Error was incorrectly calculated because the Input Measure AF and Input Measure AL values were not square-rooted. This issue has been resolved.DE121916
Previously, when you tried to run the Device Mapping Upgrade Utility with duplicate Device Mapping records present in the database, an error occurred. This issue has been resolved.DE116215