Model 25

Model 25 Description

Model 25 creates production events when the Turnup Tag value transitions from a specific value to another specific value.  The format of the Event Number is [XXX###].  The Event Number is created using the first 3 characters (XXX) of the previous event and adding one to the event count that is contained in the last 3 characters. 

The functionality in this model is available only if you have purchased the Quality Module.

Model 25 Properties

The following Model properties are set up using the Plant Applications Administrator:

Property

Description

Maximum Run Time (Seconds)

optional: Type the number of seconds you want the model to run. The default is 0 (zero), which means the model will not time out. Typically, you will want to limit the run time of the model only if troubleshooting the model (for example, one of the stored procedures is in an infinite loop).

Model Processing Group

Used for multithreading. See the Multithreading topic for more information.

Turnup Tag

The tag used to trigger the creation of a new production event.

From Value

The Value the Batch Tag must transition FROM to trigger the creation of a new production event.

To Value

The Value the Batch Tag must transition TO in order to trigger the creation of a new production event.

See Also