Model 26

Model 26 Description

Model 26 creates production events when the Turnup Tag has a value change.  The Tappi or Event Number is the value of the Turnup Tag and the Tappi Begin parameter.

The functionality in this model is available only if you have purchased the Quality Module.

Model 26 Properties

The following Model properties are set up using the Plant Applications Administrator:

Property

Description

Maximum Run Time (Seconds)

optional: Type the number of seconds you want the model to run. The default is 0 (zero), which means the model will not time out. Typically, you will want to limit the run time of the model only if troubleshooting the model (for example, one of the stored procedures is in an infinite loop).

Model Processing Group

Used for multithreading. See the Multithreading topic for more information.

Turnup Tag

A value change of this tag is used to trigger a new production event to be created.

Tappi Begin

This value is used as the 1st characters of the Tappi or Event Number.

See Also