Model 34 Description

Set Events are created whenever a new event is manually created on the Production Unit Model 34 is set up on.  The Set Events are based on the value in the SetsTag and the Sets PU_Id.  The SetsTag indicates the number of sets to create and the Sets PU_Id indicates the Production Unit to create the events on.

The functionality in this model is available only if you have purchased the Quality Module.

Model 34 Properties

The following Model properties are set up using the Plant Applications Administrator:

Property

Description

Maximum Run Time (Seconds)

optional: Type the number of seconds you want the model to run. The default is 0 (zero), which means the model will not time out. Typically, you will want to limit the run time of the model only if troubleshooting the model (for example, one of the stored procedures is in an infinite loop).

Model Processing Group

Used for multithreading. See the Multithreading topic for more information.

SetsTag

This value is used to indicate the Number of Sets to create.

Sets PU_Id

If sets events are to be created this is the PU_Id to create the new set events on.