Feeder Protection
GE Vernova’s distribution feeder protection systems provide advanced protection with flexibility, programmability and communications for maximum system reliability. Our highly skilled engineers and technicians understand distribution feeder principles and the sources of faults on overhead and underground distribution feeders. They apply their knowledge to the design and manufacture of some of the most advanced protection relays and systems in the world.
Feeder Protection
GE Vernova’s distribution feeder protection systems provide advanced protection with flexibility, programmability and communications for maximum system reliability. Our highly skilled engineers and technicians understand distribution feeder principles and the sources of faults on overhead and underground distribution feeders. They apply their knowledge to the design and manufacture of some of the most advanced protection relays and systems in the world.

P84 MiCOM 5th Generation
The P84, part of the MiCOM P40 Agile 5th Generation family, delivers high performance processing and a graphical HMI as standard. A cost-effective range of transmission/sub-transmission class protection relays providing multi-functional line terminal protection with autoreclose and check synchronising features. This range of products is ideal for HV, EHV and UHV applications on lines and cables for 1 or 2 breaker applications with patented adaptive auto-reclose functionality.

MiCOM P14x Agile
The P14x series of feeder protection relays, part of the MiCOM P40 Agile family of protection relays, provide an integrated solution for the complete protection, control and monitoring of overhead lines and underground cables. Modular range in 4U high, 40TE (4") 60TE (6") and 80TE (8") width.

Multilin F60
The F60, a member of the UR family of protection relays, provides high performance feeder protection, control and monitoring of overhead lines and underground cables. It offers a large color LCD display for bay control & monitoring applications, integrated PMU and process bus.


Multilin 850
With comprehensive, advanced feeder protection functions, the 850 supports both industrial and distribution utility feeders. Dual feeders (850D) and multi feeder (850P) in electrical applications are also supported. Wi-Fi connectivity to configure settings and retrieve records and integrated arc flash protection.

Multilin Agile Feeder Protection
Multilin Agile is a compact, high performance protection and control solution for distribution and industrial feeders. This powerful device hosts a graphical color screen for bay monitoring and control. It also provides advanced functionality, including high-performance protection, extensive monitoring & control functions, redundant Ethernet communication, and flexible configuration capabilities in a compact form factor (6” wide)

P40 Agile Enhanced P14N, P14D, P94V
The P14N non-directional overcurrent protection, P14D directional overcurrent protection and P94V voltage & frequency protection relays are ideal for feeder protection, control and monitoring of overhead lines, underground cables and distributed generation interconnections. Easy upgrade for K-series relays. Advanced features for TGFD, TCS, df/dt, dv/dt, voltage vector shift, high impedance fault, load encroachment, switch onto fault and fault locator.

Not finding the feeder product that you’re looking for? View legacy feeder protection products.
Recommended Products & services
Generator Protection
GE Vernova's generator protection devices provide innovative solutions for the protection, control and monitoring of generator assets. Generator protection is critical to maintaining maximum uptime in the generating facility and providing vital protection of the generating unit. From the protection and control of utility generators to ensuring safe interconnection of renewable energy sources, to synchronization and load shedding solutions using advanced automation, GE Vernova maximizes asset reliability and operational life.
Generator Protection
GE Vernova's generator protection devices provide innovative solutions for the protection, control and monitoring of generator assets. Generator protection is critical to maintaining maximum uptime in the generating facility and providing vital protection of the generating unit. From the protection and control of utility generators to ensuring safe interconnection of renewable energy sources, to synchronization and load shedding solutions using advanced automation, GE Vernova maximizes asset reliability and operational life.

Multilin G60
The G60, a member of the UR family of protection relays, provides ultimate protection for AC generators. Provides 100% stator ground fault by low frequency injection (GPM-S module required) and field ground fault protection (GPM-F module required). With its 7-Slot variant, it is capable to also protect the associated elevator transformers. It offers a large color LCD display, integrated PMU and process bus and is on the US Government GSA schedule

MiCOM P34x Agile
The P34x models, members of the MiCOM P40 Agile family of protection relays, offer cost effective protection for AC generators. They can provide 100% stator ground fault by low frequency injection (P345, GPM-S module required) and field ground fault protection (P391 module required).

Multilin GPM-S
The GPM-S is a Stator Ground Protection Module that provide 100% stator ground fault protection during generator start-up, running and stopped conditions. It is based on sub-harmonic injection of a 20Hz voltage to continuously monitor the integrity of the stator windings. The GPM-S can be used with either of the Multilin G60 or the MiCOM Agile P345 relays.

Multilin GPM-F
The GPM-F is a Ground Protection Module for monitoring the generator field/rotor windings. Working in combination with the Multilin G60 relay, the GPM-F provides detection of ground faults in the field winding of the generator. The device can be used for either single point or double point injection based on application requirements
Not finding the generation product that you’re looking for? View legacy generation protection products.
Recommended Products & services
VCB V-Type Center Break Disconnectors up to 145 kV
The VCB, rated from 72.5 to 145 kV, is a V-type center break disconnector on which both insulators rotate to open and close the switch. Structural and civil work costs are kept to a minimum thus reducing overall installation costs. The galvanized structural steel channel base provides high strength and rigid design, while flex technology provides long term operation.
VCB V-Type Center Break Disconnectors up to 145 kV
The VCB, rated from 72.5 to 145 kV, is a V-type center break disconnector on which both insulators rotate to open and close the switch. Structural and civil work costs are kept to a minimum thus reducing overall installation costs. The galvanized structural steel channel base provides high strength and rigid design, while flex technology provides long term operation.
Recommended Products & services
S3CVS Vertical Break Disconnectors up to 72 kV
The S3CVS is a heavy duty vertical break disconnector suitable for high current installations such as generator busbar disconnectors for power plants, electrical brake generators, SVC plants, as well as feeding furnaces and electrolytic plants. Rated from 24 to 72 kV, the S3CVS can be supplied completely assembled with a simple three phase base.
S3CVS Vertical Break Disconnectors up to 72 kV
The S3CVS is a heavy duty vertical break disconnector suitable for high current installations such as generator busbar disconnectors for power plants, electrical brake generators, SVC plants, as well as feeding furnaces and electrolytic plants. Rated from 24 to 72 kV, the S3CVS can be supplied completely assembled with a simple three phase base.
Recommended Products & services
S3CVL Vertical Break Disconnectors up to 550 kV
The S3CVL, rated from 245 to 550 kV, is a modern, 3 insulator vertical break disconnector equipped with the unique L-Contact. Corrosion free materials mean virtually no maintenance is required. Specific spark-free solutions with an SF₆ breaking chamber are available for EHV applications.
S3CVL Vertical Break Disconnectors up to 550 kV
The S3CVL, rated from 245 to 550 kV, is a modern, 3 insulator vertical break disconnector equipped with the unique L-Contact. Corrosion free materials mean virtually no maintenance is required. Specific spark-free solutions with an SF₆ breaking chamber are available for EHV applications.
Recommended Products & services
S3CV Vertical Break Disconnectors up to 245 kV
GE Vernova’s S3CV vertical break disconnector is rated from 52 to 245 kV. Rigid and well supported terminal pads permit post insulators and additional space savings. The S3CV can be supplied or easily retro-fitted with 1 or 2 earthing switches, and customizable solutions are available for vertical, underhung and phase-to-phase installations.
S3CV Vertical Break Disconnectors up to 245 kV
GE Vernova’s S3CV vertical break disconnector is rated from 52 to 245 kV. Rigid and well supported terminal pads permit post insulators and additional space savings. The S3CV can be supplied or easily retro-fitted with 1 or 2 earthing switches, and customizable solutions are available for vertical, underhung and phase-to-phase installations.
Recommended Products & services
BCVB Vertical Break Disconnector up to 800 kV
GE Vernova’s BCVB vertical break disconnector, rated from 420 to 800 kV, reduces phase spacing to a minimum. BCVB is reliable in adverse conditions (-50°C to +50°C), and operates under 0 to 20 mm of ice. The double movement ensures high short circuit rating and excellent ice breaking. BCVB is robust and easy to operate.
BCVB Vertical Break Disconnector up to 800 kV
GE Vernova’s BCVB vertical break disconnector, rated from 420 to 800 kV, reduces phase spacing to a minimum. BCVB is reliable in adverse conditions (-50°C to +50°C), and operates under 0 to 20 mm of ice. The double movement ensures high short circuit rating and excellent ice breaking. BCVB is robust and easy to operate.
Recommended Products & services
Multilin Agile Motor (P24N/D) Protection Series
GE Vernova’s Multilin Agile Motor Protection, with its compact footprint and advanced feature set, helps to decrease spending to achieve better outcomes.
The Multilin Agile platform offers dedicated motor protection relay with basic to advanced features based on the motor size and application. The relay supports GE Vernova’s proven thermal model for reliable motor protection along with various independent stages of functions to protect against electrical & mechanical faults including Overcurrent /overvoltage/Power & frequency protection.
Multilin Agile Motor (P24N/D) Protection Series
GE Vernova’s Multilin Agile Motor Protection, with its compact footprint and advanced feature set, helps to decrease spending to achieve better outcomes.
The Multilin Agile platform offers dedicated motor protection relay with basic to advanced features based on the motor size and application. The relay supports GE Vernova’s proven thermal model for reliable motor protection along with various independent stages of functions to protect against electrical & mechanical faults including Overcurrent /overvoltage/Power & frequency protection.
Overview
Multilin Agile Feeder P24DB Functional Block Diagram

Device Number | Function |
---|---|
14 | Speed Switch Input |
27p | Phase Undervoltage |
27_1 | Positive Sequence Undervoltage |
32 | Phase directional power |
32R | Reverse Power protection |
37 | Undercurrent |
46 | Current Unbalance |
47 | Phase reversal |
49 | Thermal Model |
50 | Phase Definite Time Overcurrent |
51 | Phase Inverse Time Overcurrent |
50N/G | Neutral/Ground Definite Time Overcurrent |
Device Number | Function |
---|---|
51N/G | Neutral/Ground IDMT Overcurrent |
SEF | Sensitive Earth Fault |
50BF | CB Failure |
48/50LR | Mechanical Jam (Start/Stalled Protection) |
52 | Breaker and Isolator Control |
55 | Power Factor |
59P | Phase Overvoltage |
59_1 | Positive Sequence Overvoltage |
59_2 | Negative Sequence Overvoltage |
59N | Neutral Voltage Displacement |
Device Number | Function |
---|---|
66 | Number of starts limitation (start supervision) |
67P | Directional Phase Overcurrent |
67N/G | Directional Neutral/Ground Overcurrent |
68 | Inrush Blocking |
81O | Overfrequency |
81U | Underfrequency |
81V | Undervoltage Blocking |
86 | Latching output contacts (Lockout)/Start inhibit |
87RGF | Restricted ground fault (REF) |
ABS | Anti-Backspin (Timer based) |
Device Number | Function |
---|---|
CTS/VTS | CT and VT Supervision |
THD | Harmonic Measurement/Protection |
DC Supply Monitoring | |
CB Condition Monitoring | |
Overload Alarm | |
Emergency Restart | |
Reduced Voltage Starting | |
Motor Start Records | |
Motor Health Report |
Advanced Motor Health Report
The Multilin Agile health report provides a quick snapshot of the motor operating and diagnostic information in an easy way to allow users to make decisions about health of the motor. Based on the graphical representation and trend values of the motor historical data gathered by the Multilin Agile, users can quickly identify process issues and maintenance requirements before damage occurs and costly repairs are required.
The motor health report quickly provides a motor operation summary with detailed information in seven categories.
- Device Overview
- Status Overview
- Trip Summary
- Motor Operating History
- Motor Starting Learned Data
- Motor Start Records
- Motor Stopping/Tripping

Advanced Communications
Three communication ports are standard: a rear serial port providing remote communications, a front USB port and rear Ethernet for device configuration and management.
Two additional Ethernet ports can be ordered to achieve Ethernet communication redundancy.
Supported Communication Protocols Include:
- Modbus (RS485 serial or Ethernet)
- IEC 60870-5-103
- DNP 3.0 (RS485 serial or Ethernet)
- IEC 61850 Ed. 2 with concurrent serial connection
- Redundant Ethernet protocols PRP, HSR, and failover also available with dual RJ45 or dual fiber media
Flexible Hardware
- Space-saving 4U height with 4” (20TE) and 6“ (30TE) case size options
- Wide choice of opto-isolated binary inputs and output relays
- Binary inputs ESI 48-4 EB2 compliant – avoids spurious pickup from induction on field wiring
- High density I/Os in various combinations depending on case size option
- Ungrouped binary inputs for trip circuit supervision
- Field upgradeable, avoiding costly hardware change
- 6” (30TE) models can accommodate:
- 1 x RS485/IRIG-B interface
- Up to 3 x RJ45/fiber optic ports for single and redundant Ethernet plus additional engineering access
- From 11 to 30 binary inputs, and 9 to 25 relay outputs, depending on the order code
- 4” (20TE) models can accommodate:
- 1 x RS485/IRIG-B interface
- 1 x RS485 additional interface
- Up to 3 x RJ45/fiber optic ports for single and redundant Ethernet plus additional engineering access
- Up to 11 binary inputs and 11 binary outputs or 14 binary inputs and 9 binary outputs, depending on the order code
Simulation & Testing
To aid commissioning, a simulation feature is provided to test the relay’s functionality and response to programmed conditions, without the need for external AC voltage and current inputs. When placed in simulation mode, the relay suspends reading actual AC inputs, generates samples to represent the programmed phasors, and loads these samples into the memory to be processed by the relay. Normal (pre-fault), fault, and post-fault conditions can be simulated to exercise a variety of relay features. Other test operations - such as an LED lamp test for each color, contact input states, and testing of output relays - are also possible.
Application Model Selection
Model | Hardware Base | Intended Application | Case Size |
---|---|---|---|
P24NB | P24N | Motor Protection (current elements only) | 20TE/30TE |
P24DB | P24D | Motor Protection (current voltage & power elements) | 20TE/30TE |
Intuitive User interface
The front HMI hosts a fully-graphical color screen. The front panel supports start, stop, local/remote, and direct function key access, facilitating the control of connected motor and managing up to six controllable devices. These replace traditional hardwired control scheme switches and annunciation, saving on engineering time and wiring costs.
Sixteen tricolor LED lamps are available, freely configurable, in addition to four fixed-function LEDs that provide a cost-effective solution for annunciation.
Multiple language are supported with easy switching between English and an additional language on the local display without uploading new firmware.
A USB front port allows ready access by field personnel’s laptop computers.

Intuitive Graphical Display

Intuitive User interface – Compact Version
The front HMI hosts a multi-line text display which allows direct device interaction. Smart dependencies within the menu ensure that settings for unused elements are hidden.
Four tricolor LED lamps are available, freely configurable, in addition to four fixed-function LEDs which provide a cost-effective solution for annunciation.
Multiple language are supported with easy switching between English and an additional language on the local display without uploading new firmware.
A USB front port offers ready access by field personnel’s laptop computers.