Manufacturing for this product has been discontinued. As an alternative, please refer to F35 or DIAC/DIFC/DSFC relays.

MIC Digital Overcurrent Relay - Legacy

Manufacturing for this product has been discontinued. As an alternative, please refer to F35 or DIAC/DIFC/DSFC relays.

Manufacturing for this product has been discontinued.

MIB High Impedance Busbar Differential Relay

Manufacturing for this product has been discontinued.

The MGC1000 are microprocessor based, digital type, generator protection relays which provide thermal protection for three phase generators, phase fault, ground fault, and unbalanced current protection.

Applications
  • Small generators
Protection & Control
  • Unbalance or current reversal
  • Thermal protection

MGC Digital Generator Protection Relay

The MGC1000 are microprocessor based, digital type, generator protection relays which provide thermal protection for three phase generators, phase fault, ground fault, and unbalanced current protection.

Applications
  • Small generators
Protection & Control
  • Unbalance or current reversal
  • Thermal protection

Manufacturing for MFF has been discontinued.

MFF relays are microprocessor based relays that provide protection against frequency variations in AC systems.

Applications
  • AC systems
Protection and Control 
  • Under and overfrequency

MFF Digital Frequency Relay - Legacy

Manufacturing for MFF has been discontinued.

MFF relays are microprocessor based relays that provide protection against frequency variations in AC systems.

Applications
  • AC systems
Protection and Control 
  • Under and overfrequency

Manufacturing for these products have been discontinued

The M Family is a new generation of modular microprocessor protective relays based on a common platform. The M Family offers a competitive solution that combines protection, monitoring, widely accepted communications standards, and flexible configuration tools for many applications. Each product within the M Family may be used as a stand alone unit or as a component of an automated substation or industrial protection and control system.

M Family Modular Microprocessor Relays - Legacy

Manufacturing for these products have been discontinued

The M Family is a new generation of modular microprocessor protective relays based on a common platform. The M Family offers a competitive solution that combines protection, monitoring, widely accepted communications standards, and flexible configuration tools for many applications. Each product within the M Family may be used as a stand alone unit or as a component of an automated substation or industrial protection and control system.

Expanding existing switchgear or installing new metering capability can be challenging due to space limitations, downtime and installation and equipment costs. GE Vernova’s Multilin™ Meter Enclosure is a pre-wired configured, economical solution for both retrofit expansions and small scale meter installations that allows the expansion of existing switchgear capability without expensive and time-consuming design.

Meter Enclosures

Pre-wired & Configured Metering Solution

Expanding existing switchgear or installing new metering capability can be challenging due to space limitations, downtime and installation and equipment costs. GE Vernova’s Multilin™ Meter Enclosure is a pre-wired configured, economical solution for both retrofit expansions and small scale meter installations that allows the expansion of existing switchgear capability without expensive and time-consuming design.

Meter Enclosure Assembly

The installation of GE Vernova’s Multilin Meter Enclosure provides customers with a simple, easy to install solution that adds advanced metering capabilities while minimizing system downtime.

The Multilin Meter Enclosure is UL/cUL certified and NEMA 1 rated, making it ideal for indoor environments. It is provided in two voltage configurations (120-240V and 277V) to ensure compatibility with existing systems.

Each meter enclosure is pre-wired and configured with an EPM meter, voltage fuses, shorting block for current transformers and a control power transformer (for 277V power systems), eliminating field wiring and installation issues.

Meter Enclosure

Typical Wiring

Enclosure Typical Wiring (120V model) Wye Wiring for 120V Model
Enclosure Typical Wiring (277V model) Wye Wiring for 277V Model
Dimensions
Enclosure Dimensions
Enclosure Dimensions

Key Features

  • Thermal model biased with RTD and negative sequence current feedback
  • Start supervision and inhibit
  • Mechanical jam
  • Voltage compensated acceleration
  • Undervoltage, overvoltage
  • Underfrequency
  • Stator differential protection
  • Thermal overload
  • Overtemperature protection
  • Phase and ground overcurrent
  • Current unbalance
  • Power elements
  • Torque protection
  • Dual overload curves for 2 speed motors
  • Reduced voltage starting control
Protection & Control

The 469 is a digital motor protection system designed to protect and manage medium and large motors and driven equipment. It contains a full range of selectively enabled, self contained protection and control elements as detailed in the Functional Block Diagram and Features table.

469 block diagram

Key Features

  • A, V, W, var, VA, PF, Hz, Wh, varh, demand
  • Torque, temperature (12 RTDs)
  • Event recorder
  • Oscillography & Data Logger (trending)
  • Statistical information & learned motor data
Monitoring & Metering

The 469 includes high accuracy metering and recording for all AC signals. Voltage,current, RTD and power metering are built into the relay as a standard feature.

Metering

The following system values are accurately metered and displayed: Phase, differential and ground currents, average current, motor load, current unbalance. Phase-to-ground and Phase-to-phase voltages, average phase voltage, system frequency. Real, reactive, apparent power, power factor, watthours, varhours, torque Current and power demand. Analog inputs and RTD temperatures. Thermal capacity used, lockout times, motor speed

Monitoring

The 469 is equipped with monitoring tools to capture data. The following information is presented in a suitable format.

Event Recorder

The event recorder stores motor and system information with a date and time stamp each time a system event occurs. Up to 256 events are recorded.

Oscillography

The 469 records up to 128 cycles with 12 samples per cycle of waveform data for 10 waveforms (Ia, Ib, Ic, Ig, Diffa, Diffb, Diffc, Va, Vb, Vc) each time a trip occurs. The record is date and time stamped.

Advanced Motor Diagnostics

The Multilin 469 provides advanced motor diagnostics including a broken rotor bar detection function. The broken rotor bar detection is a condition maintenance function that continuously monitors the motor’s health while in operation. The advanced Motor Current Signature Analysis (MCSA) continuously analyzes the motor current signature and based on preset algorithms will determine when a broken rotor bar is present in the motor.

View motor status using digital inputs, analog inputs and RTD inputs View motor status using digital inputs, analog inputs and RTD inputs

Key Features
  • Multiple Ports - 10baseT Ethernet, RS485, RS232, RS422, DeviceNet
  • Multiple Protocols - Modbus RTU, Modbus TCP/IP, DeviceNet

     

Front Panel
Multilin 469 Front Panel

EnerVista™ Software

The EnerVista™ Suite is an industry leading set of software programs that will simplify every aspect of using the 469 relay. Tools to monitor the status of your motor, maintain your relay, and integrate information measured by the 469 into HMI or SCADA monitoring systems are available. Also provided are the utilities to analyze the cause of faults and system disturbances using the powerful Waveform and Sequence of Event viewers that come with the 469 Setup Software that is included with each relay. Learn More

Motor Settings Auto-Configurator Create complete settings files for your SR469 in 6 simple steps using the Motor Settings Auto-Configurator.

8 Series Retrofit Kit

8 Series Retrofit Kit Explore the 8 Series Retrofit Kit
Retrofit Existing SR 469 Devices to the Multilin 869 in Minutes

Traditionally, retrofitting an existing relay has been a challenging, time consuming task often requiring re-engineering, new drawings, panel modifications, re-wiring and re-testing.

The 8 Series Retrofit Kit provides a quick, 3-step solution to upgrade previously installed SR 469 relays. With the new 8 Series Retrofit Kit users are able to install the 869 Motor Protection System without modifying existing cutouts and wiring, and without any drawing changes or re-engineering time.

Buy 469 to 869 Retrofit Kit

Easy 3-Step Process to Upgrade in as Fast as 21 Minutes

EnerVista 8 Series Setup Software provides automated setting file conversion. Once completed, a graphical report is provided to verify and call out any settings that need attention.

Simply remove the terminal blocks and then remove the SR chassis from the panel. No need to disconnect any of the field wiring.

Insert the new 8 Series Retrofit chassis into the switchgear and simply plug-in the old terminal blocks - there is no need to make any cut-out modifications or push and pull cables.

The 3 Series family of protection relays are functional and economical protection solutions for feeders, motors and transformers. By providing protection, control, monitoring and metering, and both local and remote user interfaces in one assembly, the 3 Series family effectively eliminates the need for expensive discrete components. The 3 Series family provide extensive diagnostic information allowing users to troubleshoot and minimize downtime.

Multilin 3 Series

Intuitive industrial and utility protective relays for feeders, motors and transformers

The 3 Series family of protection relays are functional and economical protection solutions for feeders, motors and transformers. By providing protection, control, monitoring and metering, and both local and remote user interfaces in one assembly, the 3 Series family effectively eliminates the need for expensive discrete components. The 3 Series family provide extensive diagnostic information allowing users to troubleshoot and minimize downtime.

Key Features
  • Event Recorder: 256 events with 1ms time stamping
  • Oscillography with 32 samples per cycle and digital states
  • IRIG-B clock synchronization
  • Motor health diagnostics
  • Security audit trail

Monitoring & Metering

 

Preventative Maintenance:

The 3 Series allows users to track relay exposure to extreme environmental conditions by monitoring and alarming at high temperatures. This data allows user to proactively schedule regular maintenance work and upgrade activities.

Failure Alarm

The 3 Series detects and alarms on communication port and IRIG-B failures. The 3 Series also enables users to analyze system performance via diagnostics information such as event records, oscillography, etc.

Statistical Data

The 3 Series records statistical data in order to assist in diagnosing common motor faults, as well as assisting in planning preventative maintenance.

Advanced Device Health Diagnostics

The 3 Series performs comprehensive device health diagnostic tests during startup and continuously at runtime to test its own major functions and critical hardware. These diagnostic tests monitor for conditions that could impact and present device status.

Key Features
  • 4 X20 character LCD display
  • Control panel with up to 12 LED indicator
  • Front USB and rear serial, Ethernet and Fiber ports
  • Multiple protocols - IEC 61850, ModBus™ RTU, ModBus™ TCP/IP, DNP 3.0, IEC60870-5-104, IEC60870-5-103

Advanced Communications

 
Easy integration into new or existing infrastructure

With several Ethernet and serial port options, and a variety of communication protocols, the 3 Series provides advanced and flexible communication selections for new and existing applications.

The 3 Series supports various industry standard protocols such as, IEC 61850, Modbus RTU, Modbus TCP/IP, DNP3.0, IEC 60870-5-103 and IEC 60870-5-104 providing simplified and easy integration into new and existing applications.

Drawout Construction 

The 3 Series offers a complete drawout feature eliminating the need for rewiring after testing has been concluded. With our advanced draw-out construction, the 3 series can be drawn-out without having to disconnect any communication cables. e.g. fiber, copper, RJ45, etc and helps retain communication status even after a relay has been withdrawn from its case.

advanced drawout communications The 3 Series’s advanced draw-out construction allows removal without disconnecting rear communications cables.

Front Panel

front panel display
Display

A 4 line liquid crystal display (LCD) allows visibility under varied lighting conditions. When the keypad and display are not being used, system information is displayed by scrolling through a maximum of 30 user-defined default messages. These default messages appear only after a user-defined period of inactivity. The metering summary page is displayed to show original metered values.

EnerVista™ software

The EnerVista suite is an industry leading set of software programs that simplifies every aspect of using a 3 Series Relay. The EnerVista suite provides all the tools to monitor the status of the protected asset, maintain the relay, and integrate the information measured into DCS or SCADA monitoring systems. Convenient COMTRADE and sequence of event viewers are an integral part of the set up software and are included to ensure proper protection and system operation. Learn More
Enervista software screens

Security - enabling NERC CIP compliance

Access Control 

Multilin devices and relays are designed with simple but powerful security to enable reliability and compliance for virtually any project or implementation. With support for multi-level permissions and multi-factor supervisory controls, Multilin devices can help you manage the integrity of your system during commissioning, testing, implementation, and beyond. The 3 Series family provides separate authentication for settings and commands to the system. In addition, as discrete authentications for local and remote access, it also provides a supervisory control factor that can lock or unlock a device for configuration changes and other modifications.

Intrusion Detection

Multilin’s family of protection and control products can also help enable your security perimeter and intrusion detection programs. By providing essential alarming and logging of critical events, Multilin devices can help you detect potential breaches within your system and allow you to respond quickly and effectively. Specifically, unsuccessful access attempts are logged, alarmed, and lead to potential attackers being locked out. This ensures the reliability of your system during questionable activity control factor that can lock or unlock a device for configuration changes and other modifications.

auditing and reporting
Auditing and Reporting 

With the Security Audit Trail reporting feature and support for Event logging of key activities such as configuration changes, Multilin devices can help ensure device and protection system integrity, and perform forensic auditing of activities and changes for compliance.

Manufacturing for the 369 has been discontinued. As an alternative, please refer to 859.

Multilin 369 - Legacy

Integrated protection and control for medium sized AC motors

Manufacturing for the 369 has been discontinued. As an alternative, please refer to 859.

Key Features

  • Enhanced thermal model
  • Stall / Jam protection
  • Undervoltage, overvoltage
  • Underfrequency
  • Thermal overload
  • Undercurrent/current unbalance
  • Variable lockout time
  • Overtemperature 12 RTDs (R option)
  • Starts/hour, time between starts
  • Voltage Phase Reversal (M option)
  • Current based phase reversal
  • Undervoltage Auto-restart

Protection & Control

The 369 is a digital motor protection system designed to protect and manage medium sized AC motors and their driven equipment. It contains a full range of selectively enabled, self contained protection and control elements as detailed in the Functional Block Diagram and Features table.

369 Block Diagram

Key Features

  • Metering - current, voltage, power, energy, frequency, RTD Temperature, Remote RTD
  • Fault diagnosis, - Event Record, Oscillography, Motor Starting Data Logger
  • Motor Health Report
  • Statistical information & learned motor data
  • Voltage/frequency/power display (M option)
  • 4 analog outputs (M option)

Monitoring & Metering

The 369 offers a choice of optional monitoring and metering functions including:

  • Actual Values
  • Metering (Option M)
  • Pre-Trip Alarms
  • Event Recorder
  • Oscillography
  • Statistical Data
  • Learned Information
  • Motor Start Data Logger
  • Testing
Motor Staring learned information Track changes in motor starting characteristics, identifying potential failures before they become critical
Motor start data logger Troubleshoot faults that occur during motor starts using the Motor Start Data logger.
369 motor start/stop and security/change histroy reports

Key Features

  • Front Panel RS232 port for programming and troubleshooting
  • Optional embedded Ethernet port
  • Optional Profibus DP/DPV1 or DeviceNet via dedicated port
  • Multiple Protocols - Modbus RTU, Modbus TCP/IP

A front RS232 port is provided for downloading setpoints and interrogating the relay using the EnerVista™ 369.
Three independent rear RS485 ports offer the customer flexibility and performance for their communication network. The 369 can
communicate at baud rates up to 19,200 bps using the industry standard Modbus® RTU protocol. Fiber optic (option F) Profibus interface (option P), DeviceNet (option D), and Ethernet (option E) ports are also available. The optional direct connect RJ45 Ethernet port can be used to connect the 369 to 10 Mbps Ethernet networks. The communication system of the 369 is designed to allow simultaneous communication via all ports.

Using Ethernet as the physical media to integrate the 369 to Local or Wide Area Networks replaces a multipoint wired
network (e.g., serial Modbus®), and eliminates expensive leased or dial-up connections, reducing operating costs.

Front Panel
369 Front panel

Display
40 Character LCD display for viewing actual values and programming setpoints Rugged, corrosion and flame retardant case

Status Indicators
4 LEDs indicate when an output is activated

Motor Status Indicators
LEDs indicated if motor Stopped, Starting, Running, Overloaded or Locked out due to an active Satart Inhibit element

Keypad
Used to display actual values, causes of alarms, causes of trips, fault diagnosis information, and to program setpoints

Computer Interface
RS232 comm part for connecting to a PC, Use for downloading setpoints, monitoring, data collection & printing reports

EnerVista™ Software

The EnerVista™ Suite is an industry leading set of software programs that will simplify every aspect of using the 369 relay. Tools to monitor the status of the motor, maintain the relay, and integrate information measured by the 369 into HMI or SCADA monitoring systems are available. Also provided are the utilities to analyze the cause of faults and system disturbances using the powerful waveform and Sequence of Event viewers that come with the EnerVista™ 369 Setup Software that is included with each relay. Learn More

Motor Settings Auto-Configurator
Motor Settings Auto-Configurator

Automatically generate a complete settings file, eliminating the need to manually program hundreds of individual protection settings.

Key Features

  • Seamless upgrade for existing Drawout Multilin 269 Motor Management Relays
  • Reduce system downtime utilizing the existing Multilin 269 Motor Management Relay drawout chassis
  • Reduce maintenance & operational costs - eliminates the need for mounting kits, re-work to existing cutouts and re-wiring of the chassis
  • Upgrade with ease using automated setting file conversion tool
  • Take advantage of newer, more advanced hardware and feature set
369 open front

The Multilin™ 350 is a member of the Multilin 3 Series protective relay platform and has been designed for the protection, control and management of feeders or related applications as a primary or backup protection device. This cost-effective protective device is used to perform advanced feeder protection, control and monitoring for low, medium and high voltage applications. The 350 also offers enhanced features such as integrated arc flash protection, metering, monitoring and diagnostics, preventative maintenance, advanced communications and security.

Multilin 350

Intuitive and innovative feeder protection system

The Multilin™ 350 is a member of the Multilin 3 Series protective relay platform and has been designed for the protection, control and management of feeders or related applications as a primary or backup protection device. This cost-effective protective device is used to perform advanced feeder protection, control and monitoring for low, medium and high voltage applications. The 350 also offers enhanced features such as integrated arc flash protection, metering, monitoring and diagnostics, preventative maintenance, advanced communications and security.

Key Features

  • Comprehensive current, voltage and frequency protection functions
  • Directional Power and Wattmetric Ground Fault
  • Wide variety of protection curves
  • Synchrocheck, CLP, 2nd Harmonic Blocking, Breaker Failure and Lockout functions
  • Cold Load Pick Up
  • Breaker failure, overload
  • Autoreclose
  • Integrated arc flash protection
Protection & Control

The 350 relay is a member of the 3 Series family of Multilin relays. This protective device is used to perform primary or back-up circuit protection on medium or high voltage feeders or transformers and down stream protection for utility and industrial switchgear. The 350 can be used for a wide variety of protection applications in power systems such as HV/MV or MV/LV transformer protection or capacitor bank protection. The basic protection provided by this relay includes multiple phase, ground, and neutral time and instantaneous overcurrent elements for coordination with upstream and downstream devices. Now it is enhanced with integrated arc flash detection functionality using light sensors supervised by over current to reduce incident energy and equipment damage. Additionally, the device provides essential feeder control features such as cold load pick up blocking, 2nd harmonic blocking, breaker failure, synchrocheck and autoreclose.

The robust 350 streamlines user work flow processes and simplifies engineering tasks such as configuration, wiring, testing, commissioning and maintenance.

Multilin 350 feeder protection relay functional block diagram
350 Functional Block Diagram
Device Number61850 Logical NodeDescription
24PVPHVolts per Hertz
25RSYNSynchrocheck
27_1psseqPTUVPositive Sequence Undervoltage
27PphsPTUPhase Undervoltage
27XauxPTUVAuxiliary Undervoltage
32PDOPDirectional Power
32NndPDOPWattmetric Ground Fault
I1/I2 OR 46BC Broken Conductor
49PTTRThermal Overload
50_2ngseqPIOCNegative Sequence Overcurrent
50BFRBRFBreaker Failure
50G/SGgndPIOC/hsePIOCGround (or Sensitive Ground) Instantaneous Overcurrent
50NndPIOCNeutral Instantaneous Overcurrent
50PphsPIOCPhase Instantaneous Overcurrent
51_2ngseqPTOCNegative Sequence Time Overcurrent
51NndPTOCNeutral Time Overcurrent
Device Number61850 Logical NodeDescription
51G/SGgndPTOC/hsePTOCGround (or Sensitive Ground) Time Overcurrent
51PphsPTOCPhase Time Overcurrent
59_2ngseqPTOVNegative Sequence Overvoltage
59NndPTOVNeutral Overvoltage
59PphsPTOVPhase Overvoltage
59XauxPTOVAuxiliary Overvoltage
60CTS CT Supervision
67G/SGgndRDIRGround (or Sensitive Ground) Directional Element
67NndRDIRNeutral Directional Element
67PphsRDIRPhase Directional Element
79RRECAutoreclose
81OPTOFOverfrequency
81UPTUFUnderfrequency
86 Lockout
CLP Cold Load Pickup
VTFF (60VTS) Voltage Fuse Failure
350 logic diagram Sixteen logic elements available for applications such as manual control, interlocking and peer to peer tripping.

Key Features

  • Comprehensive metering
  • Event Recorder: 256 events (1ms time stamping)
  • Programmable oscillography up to 32 samples per cycle and digital states and Fault Report
  • Relay health diagnostics
  • Breaker monitoring and CT/VT supervision
  • Security and password control
  • SNTP, IRIG-B or IEEE 1588 time synchronization
Power System Troubleshooting

Analyze power system disturbances with transient fault recorder and event records

Monitoring & Diagnostics
Metering, Monitoring & Diagnostics
  • IEEE 1588 (Precise Time Protocol) and IRIG-B:

    IEEE 1588 synchronizes time between different nodes on an Ethernet network when precise time synchronization is required, and IRIG-B allows time stamping of events to be synchronized among connected devices within 1 millisecond.

     

  • Trip/Close Coil Monitoring

    The 350 can be used to monitor the integrity of both the breaker trip and closing coils and circuits. The supervision inputs monitor both the auxiliary voltage levels, while the outputs monitor the continuity of the trip and/or closing circuits, by applying a small current through the circuits.

     

  • Advanced Device Health Diagnostic:

    These diagnostic tests monitor for conditions that could impact and present device status via SCADA communications and front panel display.

     

  • Advanced Device Health Diagnostic:

    These diagnostic tests monitor for conditions that could impact and present device status via SCADA communications and front panel display.

Key Features

  • Front USB and rear serial, Ethernet, fiber and dual port options for seamless redundancy (IEC 62439-3, PRP & HSR)
  • Multiple communication protocols supporting industry leading standards

Advanced Communications

The 350 incorporates the latest communication technologies, making it the easiest and the most flexible feeder protection relay for use and integration into new and existing infrastructures. The 350 relay provides the user with one front USB and one rear RS485 communication port. Also available with the 350 is a rear communication port with Ethernet Fiber and Copper. For configurations requiring PRP and HSR redundancy protocols, the 350 provides two rear Fiber ports. Through the use of these ports, continuous monitoring and control from a remote computer, SCADA system or PLC is possible.

The 350 provides optional Parallel Redundancy Protocol (PRP) and High Availability Seamless Ring (HSR) according to the IEC 62439-3 standard that defines two protocols to increase network availability by reducing failover time to zero. Both ports are capable of simultaneously supporting the following protocols: Modbus TCP/ IP, IEC 61850, DNP3 or IEC 60870-5-104, IEEE 1588, SNTP and OPC-UA.

Link Loss Alert (LLA) function detects any issue with one port and switch to the other one in case of failure.

The 350 supports popular industry-leading standard protocols enabling easy, direct integration into electrical SCADA and HMI systems. The protocols supported by the 350 include:

  • IEC 61850
  • IEC 61850 GOOSE
  • DNP 3.0
  • Modbus RTU
  • Modbus TCP/IP
  • IEC 60870-5-103
  • IEC 60870-5-104
  • PRP & HSR (IEC 62439-3)
  • Link Loss Alert (LLA)
  • OPC-UA
  • IEEE 1588 for time synchronization
Example of redundant HSR and PRP Architecture
Example of redundant HSR and PRP Architecture Redundancy protocols can be used for various networking architectures including combined PRP / HSR technologies.

EnerVista Software

The EnerVista suite is an industry leading set of software programs that simplifies every aspect of using the 350 relay. The EnerVista suite provides all the tools to monitor the status of the protected asset, maintain the relay, and integrate the information measured into DCS or SCADA monitoring systems. Convenient COMTRADE and sequence of event viewers are an integral part of the 350 set up software and are included to ensure proper protection and system. Learn More

3 Series setup software protection summary for viewing a summary of Protection & Control configuration
Access Control

With the Security Audit Trail reporting feature, available in GE Vernova’s ViewPoint Monitoring software, operators are able to obtain Event logging reports of key activities such as configuration changes. These pre-formatted reports can be used to help ensure device and protection system integrity and perform forensic auditing of activities and changes for compliance.

Security audit trail sample screen Trace any setting changes with security audit trail.

Key Features

  • 4 line display for easy viewing of key data
  • 12/10 LED indicators for quick diagnostics
  • Programmable LED indicators for specific targets
  • Draw out or non draw out design options

Hardware

Inputs and Outputs

The 350 features the following inputs and outputs for monitoring and control of typical feeder applications:

  • 10 contact Inputs with programmable thresholds
  • 2 Form A outputs for breaker trip and close with coil monitoring and 5 Form C output relays
Drawout & Non-Drawout Construction

The 350 is offered in both a drawout or a nondrawout construction. In the drawout case design the 350 simplifies installation and improves site safety as the need to open switchgear doors or rewire the device after testing is eliminated.

The 350 protection relay chassis used with a draw out relay is available separately, for use as a partial replacement or in test environments. The draw out relay with no chassis is also available to order as a spare unit.

Application Flexibility & Ease of Wiring 

Removable terminals ease wiring and in-system testing or troubleshooting.

Drawout relay

Drawout

Non-drawout relay

Non-drawout

User Interface

User Interface

Retrofit Existing Multilin MII Family Devices

Traditionally, retrofitting or upgrading an existing relay has been a challenging and time consuming task often requiring re-engineering, panel modifications and re-wiring. Similar features and form factor of some models of MII family devices allow users to replace their existing relays with 3 Series relays with enhanced protection and control features and advanced communications.

The SR3 Enervista Setup software allows users to create new setting files based on existing MIFII and MIVII setting files and can be uploaded to a 350 relay with a compatible model number. Retrofit is smooth and simplified with minor wiring or switchgear modifications.

3 Series retrofit