Economical Power and Energy Measurement

EPM 2200 Digital Power Meter

Economical Power and Energy Measurement

METERING

The EPM 2200 Power Meter is a 0.5% Accuracy Class meter, providing real-time measurement of current and voltage and offers optional support for Power, Energy, Frequency, and Power Factor measurements.

Universal Voltage and Current Inputs

The meter allows voltage inputs measurements up to 416 Volts Line to Neutral and 721 Volts Line to Line. This insures proper meter safety when wiring directly to high voltage systems. The unit will perform to specification on 69 Volt, 120 Volt, 230 Volt, 277 Volt and 347 Volt power systems.

EPM2200 Universal Voltage and Current Inputs chart

USER INTERFACE

Display, Mounting and Dimensions diagram

INSTALLATION

Unique Current Input Connections

EPM 2200 meter uses two current input wiring methods.

  • Method One - CT pass through. Directly pass the CT through the meter without any physical termination on the meter. This insures that the meter cannot be a point of failure on the CT circuit. This is preferable to utility users when sharing relay class CTs. No Burden is added to the secondary CT circuit.
  • Method Two - Current “Gills.” The meter additionally provides ultra-rugged termination pass through bars allowing the CT leads to be terminated on the meter. This also eliminates any possible point of failure at the meter. This method is also a preferred technique for ensuring relay class CT integrity does not get compromised. No terminal blocks are required and this stud based design ensures that CTs will not open under a fault condition.
Unique Current Input Connections

SPECIFICATIONS

GE Vernova EPM2200 digital Power Meter Specifications

COMMUNICATIONS

Through an optional serial Modbus communications interface, the EPM 2200 can also provide data to RTUs, PLCs and other control devices at baud rates ranging from 9600 baud to 57.6 kbaud.

BACnet Communications

The EPM 2200 meter also supports optional, simultaneous BACnet MS/TP and Modbus Ethernet communications for easy integration into BMS and electrical monitoring systems.

BACnet COMMUNICATIONS

MULTILIN METER ENCLOSURE

MULTILIN METER ENCLOSURE

Expanding existing switchgear or installing new metering capability can be challenging due to space limitations, downtime and installation and equipment costs. GE Vernova's Multilin Meter Enclosure is a pre-wired configured, economical solution for both retrofit expansions and small scale meter installations that allows the expansion of existing switchgear capability without expensive and time-consuming design.

When ordered as a meter option the enclosure provides a factory pre-wired, installation-ready metering solution that further drives energy cost savings, by enabling the measurement of key energy usage information along multiple metering points for new or existing systems.


Ordering the enclosure is simple when selected as an option during meter configuration, ensuring correct pre-wired meter-compatible delivery.

Pre-Wired, Configured and Economical Solution for Retrofit and Small Metering Systems

 

Easy and Rapid Installation
 
  • Factory pre-wired, installation-ready GE Vernova metering solution eliminates wiring and associated errors for rapid installation
  • Extend metering capability with new systems and existing switchgear without system installation downtime

     

Cost-Effective Retrofit Solution
 
  • Save up to 200% versus the addition of a new switchgear cabinet
  • Compact footprint makes effective use of existing allocated space
  • Allows new installations or the expansion of existing switchgear capability without expensive, time-consuming designs, eliminating system downtime

 

Reliable and Compatible
 
  • Backed by a two-year warranty
  • Simple meter option ordering ensures compatibility with GE Vernova EPM 2000/6010/6000/7000 meters
  • Comprehensive factory testing of both meter and enclosure together
  • NEMA1 tested and UL/CUL certified

 

Applications (New and Retrofit installations)
 
  • Industrial Multi-Tenant Monitoring
  • Commercial/Residential Buildings
  • Healthcare Institutions
  • Government Buildings
  • Manufacturing
  • Educational Campuses

     

Assembly
EPM2200 Assembly
EPM2200 Diagram

GE Vernova’s Grid Solutions has discontinued sales of EPM 2000. As an alternative, please refer to EPM 2200.

EPM 2000 - Legacy

Digital Power Meter

GE Vernova’s Grid Solutions has discontinued sales of EPM 2000. As an alternative, please refer to EPM 2200.

GE Vernova’s Grid Solutions has discontinued sales of this product. Please contact us to discuss alternatives

EPM 1000 Sub-meter - Legacy

GE Vernova’s Grid Solutions has discontinued sales of this product. Please contact us to discuss alternatives

Manufacturing for this product has been discontinued.

DTR Transformer Tap Changer Controller - Legacy

Manufacturing for this product has been discontinued.

Manufacturing for this product has been discontinued. As an alternative, please refer to the T60 or

DTP-B Digital Transformer Protection

Manufacturing for this product has been discontinued. As an alternative, please refer to the T60 or

Manufacturing for this product has been discontinued.

DRS - Legacy

Numerical Single-Phase and Three-Phase Reclosing System

Manufacturing for this product has been discontinued.

Manufacturing for this product has been discontinued.

DMS Digital Multifunction System - Legacy

Manufacturing for this product has been discontinued.

The DLPD provides distance protection for HV and EHV transmission lines. It may be used for single or three phase tripping applications. It includes four zones of distance protection. User selectable pilot schemes are provided with step distance backup. Ground instantaneous and time overcurrent

DLPD Digital Line Protection System

The DLPD provides distance protection for HV and EHV transmission lines. It may be used for single or three phase tripping applications. It includes four zones of distance protection. User selectable pilot schemes are provided with step distance backup. Ground instantaneous and time overcurrent

Single Phase Digital Overcurrent Protection 

DIAC/DIFC/DSFC - Legacy

Single Phase Digital Overcurrent Protection 

Manufacturing for this product has been discontinued. As an alternative, please refer to the MDS Orbit platform and JPAX/JMUX.

DGT Distributed Generation Trip Control - Legacy

Manufacturing for this product has been discontinued. As an alternative, please refer to the MDS Orbit platform and JPAX/JMUX.