EPM 7100 - Legacy
Power Quality Meter
GE Vernova has discontinued sales of the EPM 7100. Please contact us to discuss alternatives.
EPM 7100 - Legacy
Power Quality Meter
GE Vernova has discontinued sales of the EPM 7100. Please contact us to discuss alternatives.
MONITORING & METERING
Traceable Watt-Hour Test Pulse for Accuracy Certification
To be certified for revenue metering, power providers and utility companies need to know that the billing energy meter will perform to its stated accuracy. To verify the meter's performance and calibration, power providers use field test standards to ensure that the unit's energy measurements are correct. Since the EPM 7100 submeters are traceable revenue meters, they contain a utility grade test pulse allowing power providers to verify and confirm that the meters are performing to their rated accuracy. This is an essential feature required in all billing grade meters.
Utility Peak Demand Metering
EPM 7100 submeters provide user-configured Block Window or Rolling Window Demand. This allows you to set up a particular utility demand profile. Block Window Demand is demand used over a fixed user-configured demand period (usually 5, 15 or 30 minutes). Rolling Window Demand is a fixed window demand that moves for a user specified sub-interval period. An example is a 15 minute demand using 3 subintervals, providing a new demand reading every 5 minutes based on the last 15 minutes. Readings for kW, kVAR, kVA and PF are calculated using utility demand structures. Other parameters offer max and min capability over the user-selectable averaging period. Voltage provides a non-rolling instantaneous max and min reading, displaying the highest surge and lowest sag seen by the meter.
COMMUNICATIONS
Standard Modbus RS485 Communication
Standard communication includes an RS485 output speaking Modbus protocol. This allows the unit to be connected to any serial RS485 bus using the Modbus interface. The unit communicates easily with most building automation or other software systems. Baud rates are up to 57.6K baud to provide fast update times.
WiFi or LAN-Based Ethernet
The unit offers two Ethernet options — either an RJ45 or WiFi connection. The WiFi option allows the EPM 7100 submeter to be used on standard WiFi base stations.
IrDA Port
Use an IrDA-equipped laptop PC to program and read the EPM 7100 submeter.
KYZ Pulse
For applications in which a pulse is needed, the unit also provides a KYZ output which pulses proportional to the amount of energy consumed. This feature is used for pulse counting applications or for building management systems where serial or Ethernet protocol is not available.
EPM 7100 ADVANCED LOGGING FEATURES
Extensive Data Logging Capability
The EPM 7100 submeter has 2 Megabytes of Flash memory that give it extensive data logging capability. The EPM 7100 offers three historical logs, a limits (alarm) log and a system events log. The unit has a real-time clock that allows for time-stamping of all the data in the instrument when log events are created.
Historical Logs
Each of the three historical logs can be programmed with unique parameters consisting of any measured reading. Up to 64 parameters can be recorded per log.
Limits (Alarm) Log
The limits log provides magnitude and duration of an event. 2,048 events are available; the log provides time-stamp and alarm value.
System Events (Anti-Tampering) Log
To protect critical billing information, the meter records and logs the following with a time stamp:
Demand/energy/log resets
Password requests
System startup
Log reads
Changes to meter's programmable settings
ENERVISTA SOFTWARE
EnerVista Launchpad
EnerVista Launchpad is a powerful software package that provides users a platform to access all of the setup and support tools needed for configuring and maintaining GE Vernova Multilin products.
EnerVista Launchpad allows configuration of devices in real-time by communicating using RS232, RS485, Ethernet or modem connections. Using Launchpad as the single interface to the setup and analysis software makes it easy to enter set points, read metered values, monitor status and evaluate power quality.
Included in EnerVista Launchpad is a document archiving and management system that ensures critical documentation is up-to-date and available when needed by automatically checking for and downloading new versions of manuals, applications notes, specifications and service bulletins.
EnerVista Integrator
EnerVista Integrator is a toolkit that allows seamless integration of GE Vernova Multilin devices into new or existing automation systems by sending GE Vernova device data to HMI, DCS and SCADA systems. Included in EnerVista Integrator is:
OPC/DDE Server
GE Vernova Multilin Drivers
Automatic Event Retrieval
Automatic Waveform Retrieval
SPECIFICATIONS
USER INTERFACE
DIMENSIONS & MOUNTING
Recommended Products & services
EPM 6100 - Legacy
GE Vernova’s Grid Solutions has discontinued sales of EPM 6100. Please contact us to discuss alternatives.
EPM 6100 - Legacy
GE Vernova’s Grid Solutions has discontinued sales of EPM 6100. Please contact us to discuss alternatives.
MONITORING & METERING
Traceable Watt-Hour Test Pulse for Accuracy Certification
To be certified for revenue metering, power providers and utility companies need to know that the billing energy meter will perform to its stated accuracy. To verify the meter's performance and calibration, power providers use field test standards to ensure that the unit's energy measurements are correct. Since the EPM 6100 submeters are traceable revenue meters, they contain a utility grade test pulse allowing power providers to verify and confirm that the meters are performing to their rated accuracy. This is an essential feature required in all billing grade meters.
Utility Peak Demand Metering
EPM 6100 submeters provide user-configured Block Window or Rolling Window Demand. This allows customers to set up a particular utility demand profile. Block Window Demand is demand used over a fixed user-configured demand period (usually 5, 15 or 30 minutes). Rolling Window Demand is a fixed window demand that moves for a user specified sub-interval period. An example is a 15 minute demand using 3 subintervals, providing a new demand reading every 5 minutes based on the last 15 minutes. Readings for kW, kVAR, kVA and PF are calculated using utility demand structures. Other parameters offer max and min capability over the user-selectable averaging period. Voltage provides a non-rolling instantaneous max and min reading, displaying the highest surge and lowest sag seen by the meter.
COMMUNICATIONS
Standard Modbus RS485 Communication
Standard communication includes an RS485 output speaking Modbus protocol. This allows the unit to be connected to any serial RS485 bus using the Modbus interface. The unit communicates easily with most building automation or other software systems. Baud rates are up to 57.6K baud to provide fast update times.
WiFi or LAN-Based Ethernet
The unit offers two Ethernet options — either an RJ45 or WiFi connection. The WiFi option allows the EPM 6100 submeter to be used on standard WiFi base stations.
IrDA Port
Use an IrDA-equipped laptop PC to program and read the EPM 6100 submeter.
KYZ Pulse
For applications in which a pulse is needed, the unit also provides a KYZ output which pulses proportional to the amount of energy consumed. This feature is used for pulse counting applications or for building management systems where serial or Ethernet protocol is not available.
SPECIFICATIONS
USER INTERFACE
DIMENSIONS & MOUNTING
Recommended Products & services
EPM 6010
Building Automation Power Meter
BACnet/IP Communications and Energy Measurement
The Multilin EPM 6010 is an industry leading revenue grade power meter with native BACnet/IP communications. This meter is designed to integrate seamlessly into existing and new building management systems using the popular BACnet protocol. The meter allows users to gather data on voltage, current, power and energy usage throughout a facility.
EPM 6010
Building Automation Power Meter
BACnet/IP Communications and Energy Measurement
The Multilin EPM 6010 is an industry leading revenue grade power meter with native BACnet/IP communications. This meter is designed to integrate seamlessly into existing and new building management systems using the popular BACnet protocol. The meter allows users to gather data on voltage, current, power and energy usage throughout a facility.
BACnet/IP COMMUNICATIONS
The Multilin EPM 6010 with BACnet/IP supports building energy management strategies, LEED certification and other Green Building initiatives. By allowing users to track energy use and power quality, the meters gives users the information they need to accurately identify cost -saving measures and respond to power quality problems when they arise.
Communications Ports
The Multilin EPM 6010 provides two independent communication ports with advanced features:
IrDA port – A unique optical IrDA port allows the unit to be setup and programmed using a remote laptop without needing a communication cable. Simply point at the meter with an IrDA-equipped PC computer to configure it.
Ethernet Port – This port provides connectivity via a 10/100BaseT RJ45 connection. Modbus TCP and BACnet protocols are supported
BACnet/IP Web Interface
The Multilin EPM 6010 comes standard with a web interface. Use the BACnet/IP interface to remotely set up the BACnet/ IP configuration and track energy use with any standard web browser.
Simultaneous Communications Paths
SOFTWARE OPTIONS
EnerVista Software
EnerVista Launchpad is a powerful software package that provides users a platform to access all of the setup and support tools needed for configuring and maintaining GE Vernova Multilin Products. Launchpad allows configuration of devices in real-time by communicating using RS232, RS485, Ethernet or modem connections. Using Launchpad as the single interface to the setup and analysis software makes it simple to enter setpoints, read metered values, monitor status and evaluate power quality.
Viewpoint Monitoring
Viewpoint Monitoring is a simple-to-use, full-featured monitoring and data recording software package for small systems. Viewpoint Monitoring provides a complete HMI package that instantly puts critical real-time device data on your PC through pre-configured graphical screens with the following functionality.
Plug-&-Play Device Monitoring
System Single-Line Monitoring & Control
Annunciator Alarm Screens
Trending Reports
Automatic Event Retrieval
Automatic Waveform Retrieval
EnerVista Integrator
EnerVista Integrator is a toolkit that allows seamless integration of GE Vernova Multilin devices into new or existing automation systems by sending GE Vernova device data to HMI, DCS, and SCADA systems. Included in EnerVista Integrator is:
OPC/DDE Server
GE Vernova Multilin Drivers
Automatic Event Retrieval
Automatic Waveform Retrieval
EnerVista Viewpoint Monitoring Data Recording and Real-Time Status
BACnet Web Interface
The Multilin EPM 6010 comes standard with a web interface. Use the BACnet/IP interface to remotely set up the BACnet/ IP configuration and track energy use with any standard web browser.
INSTALLATION
Universal Voltage and Current
This meter allows voltage input measurements up to 416 Volts Line to Neutral and 721 volts Line to Line. This helps ensure proper meter safety when wiring directly to high voltage systems. The unit will perform to specification on 69 Volt, 120 Volt, 230 Volt, 277 Volt and 347 Volt power systems.
Unique Current Input Connections
EPM 6010 meter uses two current input wiring methods.
Method One - CT pass through. Directly pass the CT through the meter without any physical termination on the meter.
This insures that the meter cannot be a point of failure on the CT circuit. This is preferable to utility users when sharing relay class CTs.
No Burden is added to the secondary CT circuit.
Method Two - Current "Gills." The meter additionally provides ultra-rugged termination pass through bars allowing the CT leads to be terminated on the meter. This also eliminates any possible point of failure at the meter. This method is also a preferred technique for ensuring relay class CT integrity does not get compromised. No terminal blocks are required and this stud based design ensures that CTs will not open under a fault condition.
Through a standard Ethernet port, the EPM 6010 can easily integrate into systems using BACnet/IP or Modbus TCP.
Solid Construction with Mounting Versatility
The EPM 6010 has a rugged design for harsh environment. This is especially important in power generation, utility substation, and critical user applications. The structural and electrical design of this meter was developed based on the recommendations and approvals of many of our utility customers.
EPM 6010 can easily be mounted in a panel for generator monitoring, substation automation and more. The unique dual design combines ANSI and DIN mounting structure and allows easy installation for both new metering applications and retrofit of existing analog meters.
The unit mounts directly in an ANSI C39.1 (4" Round form) or an IEC 92 mm DIN square form.
Meter Interface
SPECIFICATIONS
EPM 6010T TRANSDUCER OPTION
GE Vernova’s Grid Solutions has discontinued sales of EPM 6010T. As an alternative, please refer to the EPM6010.
The transducer configuration comes without a display and has a DIN rail mount. It’s ideal for use in switchgear retrofit applications where access to the meter face and display is not necessary, and where budgets are a large consideration.
Features
- EPM 6010 Power Meter without display, DIN mount
- Mounts directly in ANSI C39.1 (4” round form) or and IEC 92mm DIN square form
- Uses minimal panel space with 4.25” panel depth
- BACnet/IP Protocol Communications
- 40 BACnet Objects
- Embedded HTTP Server
- 0.2% Watt-Hour Accuracy
Mounting
MULTILIN METER ENCLOSURE
Expanding existing switchgear or installing new metering capability can be challenging due to space limitations, downtime and installation and equipment costs. GE Vernova's Multilin Meter Enclosure is a pre-wired configured, economical solution for both retrofit expansions and small scale meter installations that allows the expansion of existing switchgear capability without expensive and time-consuming design.
When ordered as a meter option the enclosure provides a factory pre-wired, installation-ready metering solution that further drives energy cost savings, by enabling the measurement of key energy usage information along multiple metering points for new or existing systems.
Ordering the enclosure is simple when selected as an option during meter configuration, ensuring correct pre-wired meter-compatible delivery.
Pre-Wired, Configured and Economical Solution for Retrofit and Small Metering Systems
Easy and Rapid Installation
- Factory pre-wired, installation-ready GE Vernova metering solution eliminates wiring and associated errors for rapid installation
- Extend metering capability with new systems and existing switchgear without system installation downtime
Cost-Effective Retrofit Solution
- Save up to 200% versus the addition of a new switchgear cabinet
- Compact footprint makes effective use of existing allocated space
- Allows new installations or the expansion of existing switchgear capability without expensive, time-consuming designs, eliminating system downtime
Reliable and Compatible
- Backed by a two-year warranty
- Simple meter option ordering ensures compatibility with GE Vernova EPM 2000/6010/6000/7000 meters
- Comprehensive factory testing of both meter and enclosure together
- NEMA1 tested and UL/CUL certified
Applications (New and Retrofit installations)
- Industrial Multi-Tenant Monitoring
- Commercial/Residential Buildings
- Healthcare Institutions
- Government Buildings
- Manufacturing
- Educational Campuses
Assembly
Diagram
Recommended Products & services
EPM 6000 Power Meter
High Accuracy Power
and Energy Measurement
The Multilin™ EPM 6000 is one of the industry’s highest performance revenue grade panel meters with superior cost to performance ratio that significantly outperforms other metering products many times its price.
In addition to its 0.2% (ANSI/IEC) accuracy the EPM 6000 also provides serial or Ethernet communications options as well as Modbus and DNP3.0 Protocol support for easy integration into new or existing systems that provide visualization of asset status.
EPM 6000 Power Meter
High Accuracy Power
and Energy Measurement
The Multilin™ EPM 6000 is one of the industry’s highest performance revenue grade panel meters with superior cost to performance ratio that significantly outperforms other metering products many times its price.
In addition to its 0.2% (ANSI/IEC) accuracy the EPM 6000 also provides serial or Ethernet communications options as well as Modbus and DNP3.0 Protocol support for easy integration into new or existing systems that provide visualization of asset status.
COMMUNICATIONS
Through a built-in infra-red (IrDA) port, the meter can be programmed through a lap top computer without a physical wire connection to the meter, making programming or data download convenient and safe. Using standard high speed Modbus communications, the meter can also provide data to RTUs, PLCs and other control devices. When used with the EnerVista suite of software, the meter can be remotely monitored.
The EPM 6000 provides two independent communication ports with advanced features.
IrDA port – Uniquely the unit has an optical IrDA port allowing the unit to be set up and programmed using a remote laptop without needing a communication cable. The second port is factory selectable to be either a RS485 port or an Ethernet port with features as follows:
- RS485 Port – This port provides RS485 communication using Modbus ASCII or Modbus RTU or DNP 3.0 protocol. Baud rates are from 9600 to 57.6 kbaud
- Ethernet Port – This port provides connectivity via a 10/100BaseT RJ45 connection. Modbus TCP protocol is supported
SOFTWARE OPTIONS
EnerVista Software
EnerVista Launchpad is a powerful software package that provides users a platform to access all of the setup and support tools needed for configuring and maintaining GE Vernova’s Multilin products. Launchpad allows configuration of devices in real-time by communicating using RS232, RS485, Ethernet, or modem connections. Using Launchpad as the single interface to the setup and analysis software makes it simple to enter setpoints, read metered values, monitor status and evaluate power quality. Included in Launchpad is a document archiving and management system that ensures critical documentation is up-to-date and available when needed by automatically checking for and downloading new versions of manuals, applications notes, specifications, and service bulletins.
Viewpoint Monitoring
Viewpoint Monitoring is a simple-to-use, full-featured monitoring and data recording software package for small systems. Viewpoint Monitoring provides a complete HMI package that instantly puts critical real-time device data on your PC through pre-configured graphical screens with the following functionality.
- Plug-&-Play Device Monitoring
- System Single-Line Monitoring & Control
- Annunciator Alarm Screens
- Trending Reports
- Automatic Event Retrieval
- Automatic Waveform Retrieval
EnerVista Integrator
EnerVista Integrator is a toolkit that allows seamless integration of GE Vernova Multilin devices into new or existing automation systems by sending GE Vernova device data to HMI, DCS, and SCADA systems. Included in EnerVista Integrator is:
- OPC/DDE Server
- GE Vernova Multilin Drivers
- Automatic Event Retrieval
- Automatic Waveform Retrieval
USER INTERFACE
- RS485 Modbus Protocol up to 57.6K Baud
- Optional upgrade from serial to Ethernet communications for simplified LAN integration and multi-point connectivity
- 3 Line .56" Bright Red LED Display
- Front IRDA Port laptop communication
INSTALLATION
Unique Current Input Connections
EPM 6000 meter uses a two current input wiring methods.
- Method One - CT pass through. Directly pass the CT through the meter without any physical termination on the meter. This insures that the meter cannot be a point of failure on the CT circuit. This is preferable to utility users when sharing relay class CTs. No Burden is added to the secondary CT circuit.
- Method Two - Current “Gills.” The meter additionally provides ultra-rugged termination pass through bars allowing the CT leads to be terminated on the meter. This also eliminates any possible point of failure at the meter. This method is also a preferred technique for ensuring relay class CT integrity does not get compromised. No terminal blocks are required and this stud based design ensures that CTs will not open under a fault condition.
SPECIFICATIONS
EPM 6000T TRANSDUCER OPTION
GE Vernova’s Grid Solutions has discontinued sales of EPM 6000T. As an alternative, please refer to the EPM7000PT .
The transducer configuration comes without a display and has a DIN rail mount. It’s ideal for use in switchgear retrofit applications where access to the meter face and display is not necessary, and where budgets are a large consideration.
Features
- EPM 6000 Power Meter without display, DIN mount
- Mounts directly in ANSI C39.1 (4” round form) or and IEC 92mm DIN square form
- Uses minimal panel space with 4.25” panel depth
- Multifunction Power and Energy Meter
- 0.2% Watt-hour accuracy
- Ethernet communications
Mounting
MULTILIN METER ENCLOSURE
Expanding existing switchgear or installing new metering capability can be challenging due to space limitations, downtime and installation and equipment costs. GE Vernova's Multilin Meter Enclosure is a pre-wired configured, economical solution for both retrofit expansions and small scale meter installations that allows the expansion of existing switchgear capability without expensive and time-consuming design.
When ordered as a meter option the enclosure provides a factory pre-wired, installation-ready metering solution that further drives energy cost savings, by enabling the measurement of key energy usage information along multiple metering points for new or existing systems.
Ordering the enclosure is simple when selected as an option during meter configuration, ensuring correct pre-wired meter-compatible delivery.
Pre-Wired, Configured and Economical Solution for Retrofit and Small Metering Systems
Easy and Rapid Installation
- Factory pre-wired, installation-ready GE Vernova metering solution eliminates wiring and associated errors for rapid installation
- Extend metering capability with new systems and existing switchgear without system installation downtime
Cost-Effective Retrofit Solution
- Save up to 200% versus the addition of a new switchgear cabinet
- Compact footprint makes effective use of existing allocated space
- Allows new installations or the expansion of existing switchgear capability without expensive, time-consuming designs, eliminating system downtime
Reliable and Compatible
- Backed by a two-year warranty
- Simple meter option ordering ensures compatibility with GE Vernova EPM 2000/6010/6000/7000 meters
- Comprehensive factory testing of both meter and enclosure together
- NEMA1 tested and UL/CUL certified
Applications (New and Retrofit installations)
- Industrial Multi-Tenant Monitoring
- Commercial/Residential Buildings
- Healthcare Institutions
- Government Buildings
- Manufacturing
- Educational Campuses
Assembly
Diagram
Recommended Products & services
EPM 5350 - Legacy
Power Metering System
GE Vernova’s Grid Solutions has discontinued sales of EPM 5350. As an alternative, please refer to EPM 6000.
EPM 5350 - Legacy
Power Metering System
GE Vernova’s Grid Solutions has discontinued sales of EPM 5350. As an alternative, please refer to EPM 6000.
Recommended Products & services
EPM 5300 - Legacy
Power Metering System
GE Vernova’s Grid Solutions has discontinued sales of EPM 5300. As an alternative, please refer to EPM 6000.
EPM 5300 - Legacy
Power Metering System
GE Vernova’s Grid Solutions has discontinued sales of EPM 5300. As an alternative, please refer to EPM 6000.
Recommended Products & services
EPM 5200 Power Metering System
Please Note: The EPM 5200 has been discontinued as of April 8, 2011. As an alternative product, we recommend the EPM 6000
EPM 5200 Power Metering System
Please Note: The EPM 5200 has been discontinued as of April 8, 2011. As an alternative product, we recommend the EPM 6000
Recommended Products & services
EPM/EPM 5100 - Legacy
Drawout Power Quality Metering System
GE Vernova’s Grid Solutions has discontinued sales of EPM 5100 meters. As an alternative, please refer to EPM 6000.
Recommended Products & services
EPM 4600 Power Meter
Consolidated, Cost Effective, Multiple Point Metering
To support and implement an effective energy management strategy, a baseline of energy measurements are required. The Multilin EPM 4600 Multi-feed Power and Energy Meter is a submetering solution that allows owners and operators to quickly, accurately and centrally measure power and energy usage of specific areas to reduce operating expenses. The EPM 4600 empowers users with greater energy awareness leading to improved tenant attraction and retention and greater overall efficiency throughout facilities.
EPM 4600 Power Meter
Consolidated, Cost Effective, Multiple Point Metering
To support and implement an effective energy management strategy, a baseline of energy measurements are required. The Multilin EPM 4600 Multi-feed Power and Energy Meter is a submetering solution that allows owners and operators to quickly, accurately and centrally measure power and energy usage of specific areas to reduce operating expenses. The EPM 4600 empowers users with greater energy awareness leading to improved tenant attraction and retention and greater overall efficiency throughout facilities.
Application Example: Multi-Tenant Metering
Challenge
In a commercial shopping mall, multiple tenants distributed throughout the building and various building operation elements such as heating/cooling systems, water management, lighting and transportation (escalators/elevators) all consume energy. Often, it is difficult for building owners and operators to know the amount of energy consumed by each element.
Solution
The EPM 4600 provides a multi-feed energy submetering solution that allows owners and operators to quickly, accurately and centrally measure power and energy usage of specific areas. With its extensive communications capabilities, installation of the single multi-feed meter is simple and allows for existing secure Wi-Fi networks to be utilized to perform data collection.
User-Friendly Touch Screen Display
Two Size Options for Flexible Installation
Energy and metering information is easily presented to users via pre-configured, user friendly, optional, touch-screen, color LED displays that connect to the EPM 4600. These low power consumption, 65K color displays are available in two sizes: a larger 5.7” (PL4600-DIS5700) and a smaller 3.5” (PL4600-DIS3500) display.
User-Friendly Installation and Setup
Installation is quick and simple using the included display installation kit and a standardized 22mm panel mount, circular cutout. The lower power consumption display is remotely powered by a supplied 24VDC standard plug power supply. Each display comes with pre-configured screens and communications for plug-and-play, out of the box use. Further customization of the display settings such as changing the default display screen or communications settings are available through on-screen setup menus.
Local and Remote Display Connectivity
Communications to the display are provided via the EPM 4600 RS485 serial communications port and/or optional RJ45 Ethernet port. This allows users the capability and flexibility of installing local or remote displays depending upon visualization requirements.
User Interface: Touch Screen Display
Single Phase Energy Readings (EPM4600-S) KWatts, KW Demand, KWatt-hours
Three Phase Energy Readings (EPM4600-T) KWatts Phase A, KWatts Phase B, KWatts Phase C
Consolidate Pulse Inputs to Measure Various Energy Types
Limit Based Alarms
Single Phase Phasor Diagram (EPM4600-S)
Three Phase Phasor Diagram (EPM4600-T)
User Interface: EPM 4600
Visualize and analyze energy and maximum demand information from the EPM 4600
GE Vernova Communicator Software
GE Vernova Communicator connects to meters via serial, Ethernet or modem. It allows users to configure a meter; view real-time metered data and analyze collected information from remote EPM power meters. GE Vernova Communicator works with the entire family of EPM meters: EPM 2200, EPM 4600, EPM 6000 Series, EPM 7000 Series, EPM 9450, EPM 9650, EPM 9800 and EPM 9900 meters.
GE Vernova Communicator displays real time data from supported meters in a user-friendly, simple and powerful graphical format. The software offers many views, including capabilities to display various specific meter functionality such as:
- Voltage, Current, Power & Energy
- Time of Usage & Accumulations
- Power Quality
- Harmonics to the 255th Order
- Actual Real-time Waveform Scopes
- Alarms & Limits
- Max. & Min. for Each Parameter
- I/O Device Information
Multilin Meter Enclosure
The EPM 4600 enclosure provides a cost-effective, low commissioning effort solution with the EPM 4600 meter and component factory prewired, tested and configured greatly reducing facility and integration effort. Operator safety and ease of maintenance is provided through the NEMA 1 rating which houses standard components such as voltage fuses and shorting blocks for current transformers. The enclosure solution will work directly with 120/208 and 277/480 Volt power systems.
The enclosure can be ordered with single or three-phase configurations as per the EPM 4600 meter configuration along with the EPM 4600 supported communications (Ethernet, Serial). Optional BACnet®* and LonWorks®* enclosure protocol add-ons enable the EPM 4600 to integrate seamlessly into new and existing Building/Energy Automation Systems (BMS).
Finally the enclosure is equipped with either a user friendly, prewired and configured 3.5” or 5.7” color touchscreen display easing startup and ongoing monitoring. The display provides extensive circuit data for every load, including circuit analysis.
Meter Enclosure Dimensional Drawings
System Requirements
| VOLTAGE INPUTS |
|---|
|
| WIRING |
|---|
|
| CURRENT INPUTS |
|---|
|
| ISOLATION |
|---|
|
| TEMPERATURE RATING |
|---|
|
| SENSING METHOD |
|---|
|
| UPDATE TIME |
|---|
|
| POWER SUPPLY |
|---|
|
| COMMUNICATION |
|---|
| RS485 (COM 1 AND COM 3) |
|---|
|
| ETHERNET/WI-FI (OPTIONAL FOR COM 1) |
|---|
|
| USB (COM 2) |
|---|
|
| SHIPPING |
|---|
|
| METER ACCURACY |
|---|
|
| COMPLIANCE |
|---|
|
Recommended Products & services
EPM 4000 Sub-meter (Discontinued)
EPM 4000 is an easy to use energy/demand data logging meter suitable for multi-tenant new construction or retrofit application. The EPM 4000 is available in 3, 6, 9 or 12 meter versions to suit a large variety of multi-tenant high-rise of garden-style apartments, condos or office suites. Its rugged metal enclosure is designed for fast installation as well as tamper resistance. The integral LCD display provides access to over 50 electrical parameters in real-time or historical format.
EPM 4000 Sub-meter (Discontinued)
EPM 4000 is an easy to use energy/demand data logging meter suitable for multi-tenant new construction or retrofit application. The EPM 4000 is available in 3, 6, 9 or 12 meter versions to suit a large variety of multi-tenant high-rise of garden-style apartments, condos or office suites. Its rugged metal enclosure is designed for fast installation as well as tamper resistance. The integral LCD display provides access to over 50 electrical parameters in real-time or historical format.