DGP Digital Generator Protection – Legacy
Manufacturing for this product has been discontinued. As an alternative, please refer to G60 or DGPR.
DGP Digital Generator Protection – Legacy
Manufacturing for this product has been discontinued. As an alternative, please refer to G60 or DGPR.
Recommended Products & services
Multilin Voltage Regulator Controller - Legacy
Manufacturing for this product has been discontinued. Please contact us to discuss alternatives.
Multilin Voltage Regulator Controller - Legacy
Manufacturing for this product has been discontinued. Please contact us to discuss alternatives.
Key Features
Auto/Manual or Local/Remote control
Adjustable Voltage Bandwidth
Configurable Voltage ratio correction
Tap change time delay
Voltage runback limits
3 stage Voltage reduction
Line Drop Compensation
(forward & reverse)Reverse Power Operation & Override
Tap change inhibits
Tap position limits
Sequential and non-sequential type
Bi-directional mode of operation
Drag hands operation
3 setting groups
Volt/VAR control
Voltage regulator controllers and Capacitor bank controllers can operate as part of an integrated Volt/VAR Control (IVVC) scheme or as a Centralized Volt/VAR control (CVVC) system. The IVVC or CVVC system works to achieve two key objectives:
Optimize Voltage - through ‘Conservation of Voltage’ that leads to reduced demand, that may result in decreased generation up to 6%.
Increased efficiency- through improved power factor and reduced VAR which helps to reduce power line losses.
Voltage regulator control
Robust Design
Based on GE Vernova’s proven controller platform with tens of thousands of units installed globally, the Multilin Voltage Regulator Controller underwent extensive Accelerated Life Testing (ALT) and Highly Accelerated Life Testing (HALT) to validate accurate functionality under specified conditions and to ensure accurate performance in extreme operating conditions and harsh environments.
Mode of Operation
To provide optimal application flexibility, the Multilin Voltage Regulator Controller offers two modes or methods of operation in which the device can be implemented to control the voltage regulator: a) Manual Mode (Local Control or Remote Control). b) Automatic Mode
Manual Mode – Local Control
In this mode, it is possible to Raise or Lower the tap locally from the Push buttons that are available on the front panel of the Multilin Voltage Regulator Controller. For added operational reliability and operator safety, inhibit functions configured in the unit continue to operate as defined.
Manual Mode – Remote Control
In this mode, the commands for Tap Raise and Lower are received from SCADA or the Integrated Volt/VAR systems via communications. This communications channel can be provided via optional radio or cellular communications.
Automatic Mode
In automatic mode, the Multilin Voltage Regulator Controller compares the measured voltage to the set voltage level, and if the difference exceeds the set bandwidth (voltage limits), the Multilin Voltage Regulator Controller issues a Raise or Lower tap commands to maintain the desired voltage levels.
Key Features to Optimize Voltage Regulation:
Voltage Level (Bandcenter)
Voltage Bandwidth
Voltage Reduction
Computation Time Delay
Line Drop Compensation (LDC)
Reverse Power LDC
Reverse Power
Reverse Power Override
Voltage Runback Limits
Inhibit Operations
Overcurrent Inhibit
Overvoltage Inhibit
Under-Voltage Inhibit
Key Features
Multiple setpoint groups
Expandable inputs and outputs for advanced applications
Customized automation schemes using FlexLogic™
Automation
The Multilin Voltage Regulator Controller offers powerful I/O and programmable logic (FlexLogic™) options for advanced automation control, reducing the need and costs associated with additional programmable controllers or discrete control devices.
Set point group control
The Multilin Voltage Regulator Controller has three identical set point groups. The activation of the group can be done either from the HMI or via a Digital Input.
Virtual Inputs and Outputs
The Multilin Voltage Regulator Controller provides 32 virtual inputs and 32 virtual outputs that provide users the ability to send commands to the device. The Multilin Voltage Regulator Controller can accept commands from SCADA, through the front HMI, or front USB port to issue commands such as Raise or Lower tap position.
Command Setting
The Multilin Voltage Regulator Controller has the ability to force commands from the menu structure. This can also be achieved via the EnerVista software that runs on a PC. This simulation ensures that the Raise and Lower commands can be safely issued from a distance without using the HMI.
Drag-Hands Reset
The Drag – Hand Reset provides the ability to reset the Drag hands to the current tap position. Commands can be sent to the Multilin Voltage Regulator Controller to reset the Drag Hand position from the front HMI , from SCADA or through the front panel USB communications.
FlexLogic™
FlexLogic in the Multilin Voltage Regulator Controller, provides the ability to create customized control schemes. This minimizes the need and costs associated with auxiliary components and wiring.
Key Features
Metering - current, voltage, power, frequency, PF, Harmonics
Event Recorder - Up to 256 time tagged events
Enhanced system diagnostics & reporting
Metering & monitoring
The Multilin Voltage Regulator Controller provides high accuracy metering and recording of AC signals. The following are the parameters that are metered by the Multilin Voltage Regulator Controller
Phase-Ground Voltages (kV)
Phase to phase Voltages (kV)
Line Voltage (kV)
Phase A, B, and C currents (A)
Line Current (A)
Ground Current (A)
3-Phase Active power (KW)
3-Phase Reactive power (KVar)
3-Phase Apparent Power
Power Factor (Lag or Lead)
2nd to 8th harmonic up to 20% – for current
2nd to 8th harmonic up to 20% – for voltage
THD in 20% – for current
THD in 20% – for voltage
These metering data can be easily integrated with a customers’ database and can also be easily viewed in their SCADA or DMS system.
Event recorder
To significantly reduce time and enable more effective disturbance, post fault analysis and troubleshooting, the Multilin Voltage Regulator Controller provides an integrated event recorder and detailed diagnostic features.
Data Management and Diagnostics
The advanced disturbance diagnostic features included in the Multilin Voltage Regulator Controller includes recording functions through an enhanced Data Logger with 10 channel RMS recorder, statistics & counters.
Statistics & Counters
Multilin Voltage Regulator Controller includes two tap changer counters which records the following information:
DAILY TAP OPERATIONS
TOTAL TAP OPERATIONS
The MIN/MAX TAP in the Multilin Voltage Regulator Controller provides information on the lowest (minimum), and the highest (maximum) tap position the tap changer reached during one 24 hour day period.
Advanced Device Health Diagnostics
A comprehensive device health diagnostic test is performed by the Multilin Voltage Regulator Controller during startup and continuously at runtime to test its own major functions and critical hardware. These diagnostic tests monitor for conditions that could impact the Multilin Voltage Regulator Controller’s performance, evaluate the criticality of this impact and present device status via SCADA communications and front panel display.
Key Features
- Networking Interface
- Two Wire RS485
- Multiple Protocols (Modbus®, DNP3.0)
- Optional wireless communications
(radio or cellular) - User Interface
- Front panel USB port
- 4 line HMI Display
- 18 System status LED’s
- 6 quick setting keys
Front panel
Front Panel Quick Keys
Front panel quick keys provides direct access to key individual setting parameters
Key Features
4-Level device security to maintain authorized access only
Simplified device configuration software tool and industry leading suite of software tools to manage and maintain Multilin devices.
Security
The Multilin Voltage Regulator Controller and associated software tools provide a suite of security features that ensure only approved personnel can make changes to the device configuration or execute operational commands.
Password Security
The Multilin Voltage Regulator Controller offers multiple levels of password security to limit access control based on settings or command levels. There are four levels of password security provided:
Local Settings Access
Local Control Access
Remote Settings Access
Remote Control Access
Local Access refers to users making changes using the front USB serial port and the HMI. Remote Access refers to users making changes using the rear RS485 port.
Enervista Software
The EnerVista™ Suite is an industry-leading set of software programs that simplifies every aspect of using the Multilin Voltage Regulator Controller. The EnerVista™ suite provides all the tools to monitor the status of the protected asset, maintain the controller, and integrate information measured by the Multilin Voltage Regulator Controller into SCADA or the DMS monitoring systems. The ability to easily view sequence of events is an integral part of the setup software, as postmortem event analysis is critical to proper system operation.
Learn More
Recommended Products & services
Multilin Switch Controller - Legacy
Manufacturing for this product has been discontinued. Please contact us if you have any inquiries.
Multilin Switch Controller - Legacy
Manufacturing for this product has been discontinued. Please contact us if you have any inquiries.
Key Features
Auto/manual or Local/Remote
Cold Load Pickup
Phase IOC detection
Phase TOC detection
Neutral TOC detection
Over Voltage
Under Voltage
Voltage Unbalance
Power loss
Reverse power
FDIR/FLISR
A key driver and measurement of utility effectiveness is in the reliability of power to its customers. As many faults on overhead distribution lines are transient in nature, reclosing at the substation and installation of mid-line reclosers./switches can improve a utilities SAIDI reliability index by up to 24%.
When permanent faults occur on overhead lines, having feeders with increasing degrees or automation can greatly enhance distribution grid reliability and reduce restoration of unfaulted segments from several hours to a few seconds or minutes. A key component of these automation schemes is intelligent controllers that can integrate with FDIR systems through sharing local information and accepting control commands.
Switch Control
Robust Design
Based on GE Vernova's proven controller platform with tens of thousands of units installed globally, the Multilin DGCS undergoes extensive Accelerated Life Testing (ALT) and Highly Accelerated Life Testing (HALT) to validate accurate functionality under specified conditions and to ensure accurate performance in extreme operating conditions and harsh environments.
Modes of Operation
The Multilin DGCS Switch controller provides two modes of operation:
Remote mode
Local mode
The Multilin DGCS switch controller measures three phase voltages and currents, and based on the measurements, manages Auto-Sectionalizing functionality:
Key Features
Multiple setpoint groups
Expandable inputs and outputs for advanced applications
Customized automation schemes using FlexLogic™
Automation & Control
The Multilin DGCS offers powerful I/O and programmable logic (FlexLogic™) options for advanced automation and control, reducing the need and costs associated with additional programmable controllers or discrete control devices.
Remote Control
For both operational efficiency and reliability reasons, the Multilin DGCS provides remote control for operating switchgear. The Multilin DGCS is capable of providing both local and manual control of the switchgear.
Set Point Group Control
The Multilin DGCS has three identical set point groups. The activation of the group can be done either from the HMI or via a digital input.
Virtual Inputs and Outputs
The Multilin DGCS provides 32 virtual inputs and 32 virtual outputs that provide users with the ability to send commands to the device. The Multilin DGCS can accept commands from SCADA, through the front HMI, or front USB port to issue commands such as close or open.
Command Setting
The Multilin DGCS has the ability to force commands from the menu structure. This can also be achieved via the EnerVista™ software that runs on a PC. This simulation ensures that the close and open commands can be safely issued from a distance without using the HMI.
FlexLogic™
FlexLogic in the Multilin DGCS provides the ability to create customized control schemes. This minimizes the need and costs associated with auxiliary components and wiring
Key Features
Metering - current, voltage, power, energy, frequency, PF, Harmonics
Event Recorder - Up to 256 time tagged events
Statistics & counters
Enhanced system diagnostics & reporting
Metering & monitoring
The Multilin DGCS provides high accuracy metering and recording of all AC signals, measuring the following key parameters:
Phase-Ground Voltages (kV)
Phase to phase Voltages (kV)
Positive, Negative, Zero Sequence Voltage
Phase A, B, and C currents (A)
Positive, Negative, Zero Sequence Current Ground Current (A)
3-Phase Active power (KW)
3-Phase Reactive power (KVar)
3-Phase Apparent Power
Power Factor (Lag or Lead)
Pos. & Neg. (Import & Export) Real Energy (kWh)
Pos. & Neg. (Import & Export) Reactive Energy (kVarh)
2nd to 8th harmonic up to 20% – for current
2nd to 8th harmonic up to 20% – for voltage
THD in 20% – for current
THD in 20% – for voltage
These data points can be easily integrated into a customer's database for seamless viewing through a SCADA or DMS system like GE Vernova's PowerOn or GeNe.
Statistics & Counters
Trip Counter
Open Counter
Close Counter
KI²t Phase A Counter
KI²t Phase B Counter
KI²t Phase C Counter
Total Close/Open Operation
Maintenance Elements
The maintenance elements in the Multilin DGCS provides alarms to the system based on the maximum number of closing/opening executed commands per period of time and I²t measurements per feeder.
Event recorder
he Multilin DGCS provides an integrated event recorder and detailed diagnostic features. The sequence of events recorder offers the following features:
Up to 256 consecutive events stored
Enable or disable, operate and dropout events by set points
Phase voltage/current and power metering shot is also included and stored at each event
Advanced Device Health Diagnostics
Comprehensive device health diagnostic tests are performed by the Multilin DGCS during startup and continuously at runtime to test its own major functions and critical hardware User Interface.
Key Features
- Networking Interface
- Two Wire RS485
- Multiple Protocols (Modbus®, DNP3.0)
- Optional wireless communications
(radio or cellular) - User Interface
- Front panel USB port
- 4 line HMI Display
- 20 System status LED’s
Front panel
Key Features
4-Level device security to maintain authorized access only
Simplified device configuration software tool and industry leading suite of software tools to manage and maintain Multilin devices.
Security
The DGCS and associated software tools provide a suite of security features that ensure only approved personnel can make changes to the device configuration or execute operational commands.
Password Security
The DGCS offers multiple levels of password security to limit access control based on settings or command levels. There are four levels of password security provided:
Local Settings Access
Local Control Access
Remote Settings Access
Remote Control Access
Local Access refers to users making changes using the front USB serial port and the HMI. Remote Access refers to users making changes using the rear RS485 port.
Enervista Software
The EnerVista™ Suite is an industry-leading set of software programs that simplifies every aspect of using the DGCS Voltage Regulator Controller. The EnerVista™ suite provides all the tools to monitor the status of the protected asset, maintain the controller, and integrate information measured by the DGCS into SCADA or the DMS monitoring systems. The ability to easily view sequence of events is an integral part of the setup software, as postmortem event analysis is critical to proper system operation.
Learn More
Recommended Products & services
Multilin DGCR - Legacy
Advanced Distribution Automation Controller
Manufacturing for this product has been discontinued. Please contact us to discuss alternatives.
The Multilin DGCR is an advanced Controller for detection of faults and controlling overhead reclosers. The Multilin DGCR is compatible with many traditional and magnetic actuator reclosers and provides a great degree of flexibility in integrating with FDIR systems.
Multilin DGCR - Legacy
Advanced Distribution Automation Controller
Manufacturing for this product has been discontinued. Please contact us to discuss alternatives.
The Multilin DGCR is an advanced Controller for detection of faults and controlling overhead reclosers. The Multilin DGCR is compatible with many traditional and magnetic actuator reclosers and provides a great degree of flexibility in integrating with FDIR systems.
Key Features
- Auto/manual or Local/Remote
- Cold Load Pickup
- Phase IOC detection
- Phase TOC detection
- Neutral TOC detection
- Over Voltage
- Under Voltage
- Voltage Unbalance
FDIR/FLISR
A key driver and measurement of utility effectiveness is in the reliability of power to its customers. As many faults on overhead distribution lines are transient in nature, reclosing at the substation and installation of mid-line reclosers./switches can improve a utilities SAIDI reliability index by up to 24%.
When permanent faults occur on overhead lines, having feeders with increasing degrees or automation can greatly enhance distribution grid reliability and reduce restoration of unfaulted segments from several hours to a few seconds or minutes. A key component of these automation schemes is intelligent controllers that can integrate with FDIR systems through sharing local information and accepting control commands.
Recloser Control
Robust Design
Based on GE Vernova's proven controller platform with tens of thousands of units installed globally, the Multilin DGCR undergoes extensive Accelerated Life Testing (ALT) and Highly Accelerated Life Testing (HALT) to validate accurate functionality under specified conditions and to ensure accurate performance in extreme operating conditions and harsh environments.
Modes of Operation
The Multilin DGCR Recloser controller provides two modes of operation:
- Remote mode
- Local mode
The Multilin DGCR recloser controller measures three phase voltages and currents, and based on the measurements, manages Auto-Recloser functionality:
Typical Application of Distribution Automation solutions
(Centralied Volt/VAR control (CVVC) & Fault Detection, Isolation & Restoration(FDIR))
Above depicts a simplified distribution network and two key distribution automation solutions driving grid optimization, efficiency and reliability
Key Features
- Multiple setpoint groups
- Expandable inputs and outputs for advanced applications
- Customized automation schemes using FlexLogic™
Automation & Control
The Multilin DGCR offers powerful I/O and programmable logic (FlexLogic™) options for advanced automation and control, reducing the need and costs associated with additional programmable controllers or discrete control devices.
Remote Control
For both operational efficiency and reliability reasons, the Multilin DGCR provides remote control for operating switchgear. The Multilin DGCR is capable of providing both local and manual control of the switchgear.
Set Point Group Control
The Multilin DGCR has three identical set point groups. The activation of the group can be done either from the HMI or via a digital input.
Virtual Inputs and Outputs
The Multilin DGCR provides 32 virtual inputs and 32 virtual outputs that provide users with the ability to send commands to the device. The Multilin DGCR can accept commands from SCADA, through the front HMI, or front USB port to issue commands such as close or open.
Command Setting
The Multilin DGCR has the ability to force commands from the menu structure. This can also be achieved via the EnerVista™ software that runs on a PC. This simulation ensures that the close and open commands can be safely issued from a distance without using the HMI.
FlexLogic™
FlexLogic in the Multilin DGCR provides the ability to create customized control schemes. This minimizes the need and costs associated with auxiliary components and wiring.
Key Features
- Metering - current, voltage, power, energy,frequency, PF, Harmonics
- Event Recorder - Up to 256 time tagged events
- Statistics & counters
- Enhanced system diagnostics & reporting
Metering & Monitoring
The Multilin DGCR provides high accuracy metering and recording of all AC signals, measuring the following key parameters:
- Phase-Ground Voltages (kV)
- Phase to phase Voltages (kV)
- Positive, Negative, Zero Sequence Voltage
- Phase A, B, and C currents (A)
- Positive, Negative, Zero Sequence Current Ground Current (A)
- 3-Phase Active power (KW)
- 3-Phase Reactive power (KVar)
- 3-Phase Apparent Power
- Power Factor (Lag or Lead)
- Pos. & Neg. (Import & Export) Real Energy (kWh)
- Pos. & Neg. (Import & Export) Reactive Energy (kVarh)
- 2nd to 8th harmonic up to 20% – for current
- 2nd to 8th harmonic up to 20% – for voltage
- THD in 20% – for current
- THD in 20% – for voltage
These data points can be easily integrated into a customer's database for seamless viewing through a SCADA or DMS system like GE Vernova's PowerOn or GeNe.
Statistics & Counters
- Trip Counter
- Open Counter
- Close Counter
- KI²t Phase A Counter
- KI²t Phase B Counter
- KI²t Phase C Counter
- Total Close/Open Operation
Maintenance Elements
The maintenance elements in the Multilin DGCR provides alarms to the system based on the maximum number of closing/opening executed commands per period of time and I²t measurements per feeder.
Event recorder
The Multilin DGCR provides an integrated event recorder and detailed diagnostic features. The sequence of events recorder offers the following features:
- Up to 256 consecutive events stored
- Enable or disable, operate and dropout events by set points
- Phase voltage/current and power metering shot is also included and stored at each event
Advanced Device Health Diagnostics
Comprehensive device health diagnostic tests are performed by the Multilin DGCR during startup and continuously at runtime to test its own major functions and critical hardware User Interface.
Key Features
Networking Interface
- Two Wire RS485
- Multiple Protocols (Modbus®, DNP3.0)
- Optional wireless communications (radio or cellular)
User Interface
- Front panel USB por
- 4 line HMI Display
- 20 System status LED’s
Key Features
- 4-Level device security to maintain authorized access only
- Simplified device configuration software tool and industry leading suite of software tools to manage and maintain Multilin devices.
Security
The DGCR and associated software tools provide a suite of security features that ensure only approved personnel can make changes to the device configuration or execute operational commands.
Password Security
The DGCR offers multiple levels of password security to limit access control based on settings or command levels. There are four levels of password security provided:
- Local Settings Access
- Local Control Access
- Remote Settings Access
- Remote Control Access
Local Access refers to users making changes using the front USB serial port and the HMI. Remote Access refers to users making changes using the rear RS485 port.
EnerVista™ Software
The EnerVista™ Suite is an industry-leading set of software programs that simplifies every aspect of using the DGCR Voltage Regulator Conroller. The EnerVista™ suite provides all the tools to monitor the status of the protected asset, maintain the controller, and integrate information measured by the DGCR into SCADA or the DMS monitoring systems. The ability to easily view sequence of events is an integral part of the setup software, as postmortem event analysis is critical to proper system operation. Learn More
Recommended Products & services
DGCM Field RTU - Legacy
Manufacturing for this product has been discontinued. As an alternative, please refer to the iBox.
DGCM Field RTU - Legacy
Manufacturing for this product has been discontinued. As an alternative, please refer to the iBox.
Fault/Level Detections
Effective fault isolation is a key feature for grid reliability. The Multilin DGCM provides early warning for downstream overcurrent and earth faults. It can be programmed to isolate a faulted segment, either independently or from the remote. The Multilin DGCM also offers control, monitoring and diagnostics in one integrated, efficient design.
Overcurrent Protection
Instantaneous and time overcurrent functions are available for phase, neutral and negative sequence currents. A variety of time curves are provided, including IEEE/ANSI, IEC A/B/C/long time inverse/short time inverse, definite time and user-programmable curves.
Cold Load Pickup
The Multilin DGCM can be programmed to block instantaneous overcurrent elements, and raise the pickup time of overcurrent elements, when a cold load condition is detected. The cold load condition is detected during the closing of the breaker on a feeder that has been de-energized for a long time. The feeder inrush and motor accelerating currents during breaker closing may be above some overcurrent protection settings.
Overvoltage (OV) Detection
The phase OV protection guards voltage sensitive feeder loads and circuits against sustained OV conditions. It generates alarms when the voltage exceeds the selected voltage level for the specified time delay.
Undervoltage (UV) Detection
The phase UV detection alerts utilities against sustained UV conditions. The UV detector generates an alarm when the voltage drops below the selected voltage level after a specified time delay.
Power Loss
The Multilin DGCM can detect a power loss condition in each phase of the power distribution line. Open/close commands are blocked, unless currents and voltages of each phase fall below minimum set values.
Application Overview
Metering & Monitoring
The Multilin DGCM provides high accuracy metering and recording of all AC signals, measuring the following key parameters:
Basic Measurements
- Current: Ia, Ib, Ic, In
- Phase-to-phase and phase-to-ground voltages for bus and line: Van, Vbn, Vcn, Vbb, Vab, Vbc, Vca
- Active power (per-phase and total): Wa, Wb, Wc, W
- Reactive power (per-phase and total): VARa, VARb, VARc, VAR
- Total active, reactive and apparent energy: MWh, MVARh, MVAh
- Power factor (per-phase and total)
- Frequency
Power Quality Measurements
- Voltage sag/swell
- Current unbalance
- Demand: voltage, current, active power, apparent power, energy, temperature
- 2nd to 15th harmonic for current
- 2nd to 15th harmonic for voltage
- THD in 20% for current
- THD in 20% for voltage
Data Management & Diagnostic
Event Recorder
To enable more effective distribution, post fault analysis and troubleshooting, the Multilin DGCM provides an integrated event recorder and detailed diagnostic features. The event recorder offers:
• Storage for up to 1024 consecutive events
Trending and Data Logging
The Multilin DGCM provides a 200 channel RMS recorder for advanced disturbance diagnostic features.
The Multilin DGCM data logger helps in better understanding the analog channel behavior, by sampling at a selectable time interval rate of 1 to 60 minutes.
The Multilin DGCM event recorder enables users to analyze the sequence of events . Each event is stored with the event number, date, time and analog data of interest.
Communications
The Multilin DGCM utilizes industry standard communications technologies, making it one of easiest and flexible controllers to use and integrate into new and existing SCADA or DMS infrastructures.
Multiple Protocol Support
Multiple communication ports and protocols allow for remote control and easy access to device and system information. All communication ports are capable of simultaneous communications.
Simultaneous industry standard protocols supported:
- DNP 3.0 – Serial and Ethernet
- Modbus Serial and Ethernet
- IEC 60870-5-104
Integrated Cellular
The Multilin DGCM’s integrated cellular modem eliminates the need for external wireless devices, which reduces infrastructure costs.
Several options for MDS™ radios when purchased with enclosure:
- MDS iNET-II
- MDS TransNet
Software
Software and Configuration
The EnerVista Suite is an industry-leading set of software programs that simplifies every aspect of using the Multilin DGCM. EnerVista provides the tools to monitor the status of the protected asset, maintain the controller and integrate information measured by the Multilin DGCM into SCADA or DMS monitoring systems.
EnerVista Launchpad
EnerVista Launchpad is a powerful software package that provides users with of the setup and support tools needed for configuring and maintaining GE Vernova’s Multilin products. The setup software within Launchpad allows the configuration of devices in real-time, by communicating via serial, Ethernet or modem connections, or offline, by creating device setting files to be sent to devices at a later time.
Recommended Products & services
Capacitor Bank Controller - Legacy
Manufacturing for this product has been discontinued. Please contact us if you have any inquiries.
Capacitor Bank Controller - Legacy
Manufacturing for this product has been discontinued. Please contact us if you have any inquiries.
Key Features
- Auto/Manual or Local/Remote control
- Automatic control based on Time, Temperature, Voltage and VAR
- Control override based on Temperature and voltage
- Over/Under Voltage settings
- Perpetual calendar with time zones and day light savings Options for multiple seasons
- Close operations counters
Volt/VAR control
Voltage regulator controllers and Capacitor bank controllers can operate as part of an integrated Volt/VAR Control (IVVC) scheme or as a Centralized Volt/VAR control (CVVC) system. The IVVC or CVVC system works to achieve two key objectives:
Optimize Voltage - through ‘Conservation of Voltage’ that leads to reduced demand, that may result in decreased generation up to 6%.
Increased efficiency- through improved power factor and reduced VAR which helps to reduce power line losses.
Capacitor Bank Control
Robust Design
As a complete package, the Multilin Capacitor Bank Controller is offered in a NEMA-4 certified cabinet that is suitable for operation of harsh environments with an operating range of -40°C to + 60°C (-40°F to +140°F).
Mode of Operation
To provide optimal application flexibility, the Multilin Capacitor Bank Controller offers two modes or methods of operation in which the device can be implemented to control the Capacitor Bank:a) Manual Mode (Local Control or Remote Control). b) Automatic Mode
Manual Mode – Local Control
In this mode, it is possible to Open or Close the Capacitor Bank, locally, from the large pushbuttons located on the front panel of the Multilin Capacitor Bank Controller. For increased operational reliability and operator safety, inhibit functions configured in the unit will continue to operate as defined.
Manual Mode – Remote Control
In this mode, the commands for Open or Close of the Capacitor Bank are received via communication channels from the SCADA or an integrated Volt/VAR system. This communication channel can be provided via optional radio or cellular communications.
Automatic Mode
In automatic mode, the Multilin Capacitor Bank Controller issues commands to Open or Close the Capacitor Bank. In this mode, the Capacitor Bank is controlled
Key Capacitor Bank Control Features:
- Four Season Configuration
- Time Schedule Control
- Temperature control
- Voltage control
- VAR Control (Min Delta KVAR)
- Inhibit Controls
Key Features
- Star Neutral Overcurrent (Blown Fuse Indication)
- Customized automation schemes using FlexLogic™
- Expandable inputs and outputs for advanced applications
Protection
Reverse Power Detection
The Multilin Capacitor Bank Controller includes a Reverse Power Detection function, which defines the minimum pickup required to detect reverse power conditions.
Neutral Overcurrent Protection (Blown Fuse Condition)
In situations where the capacitor bank has been tripped due to a neutral current unbalance situation, the Multilin Capacitor Bank Controller will execute a reclose action to validate the state of the fault, ensuring the fault was not transient in nature. This automatic reclose action ensures maximizes system reliability.
Automation
The Multilin Capacitor Bank Controller offers powerful I/O and programmable FlexLogic™ options for advanced automation control, reducing the need for additional programmable controllers or discrete control relays. The Multilin Capacitor Bank Controller has three identical set point groups. The activation of the group can be done either from the HMI or via a Digital Input.
Set point group control
The Multilin Capacitor Bank Controller has three identical set point groups. The activation of the group can be done either from the HMI or via a Digital Input.
Virtual Inputs and Outputs
The Multilin Capacitor Bank Controller provides 32 virtual inputs and 32 virtual outputs that provide users the ability to send commands to the device. The Multilin Capacitor Bank Controller can accept commands from SCADA, through the front HMI, or front USB port to issue commands such as Open or Close.
Command Setting
The Multilin Capacitor Bank Controller has the ability to force commands from the menu structure accessible through the Multilin EnerVista setup software that runs on a PC.
FlexLogic™
Advanced FlexLogic in the Multilin Capacitor Bank Controller provides the ability to create customized control schemes. This minimizes the need for auxiliary components and wiring, thus reducing complexity and costs.
Key Features
- Metering - current, voltage, power, frequency, PF, Harmonics
- Event Recorder - Up to 256 time tagged events
- Temperature via RTD inputs
- Enhanced system diagnostics & reporting
Metering & monitoring
The Multilin Capacitor Bank Controller provides high accuracy metering and recording of AC signals, measuring the following key parameters:
- Phase-Ground Voltage (kV)
- Phase-to-Phase Voltage (kV)
- Line Voltage (kV)
- A, B, and C Phase Currents (A)
- Line Current (A)
- Ground Current (A)
- 3-Phase Active Power (kW)
- 3-Phase Reactive Power (kVAR)
- 3-Phase Apparent Power
- Delta Reactive Power (KVAR)
- Power Factor (Lag or Lead)
- 2nd to 8th harmonic up to 20% – for current
- 2nd to 8th harmonic up to 20% – for voltage
- THD in 20% – for current
- THD in 20% – for voltage
- Temperature [ ºC ]
These data points can be easily integrated into a customer’s database for seamless viewing through a SCADA or DMS system.
The Multilin Capacitor Bank Controller has the ability to monitor the following setpoints / conditions and issue an alarm if measured values fall outside of specified limits:
- Minimum voltage limit
- Bank switch failed
- Switching alarm (Reverse Power)
- Total close counter reached
- Max Daily operation counter reached
- Minimum VAR Delta (variation)
- Minimum Volt. Delta (variation)
- Neutral overcurrent
Event recorder
To significantly reduce time and enable more effective disturbance, post fault analysis and troubleshooting, the Multilin Capacitor Bank Controller provides an integrated event recorder and detailed diagnostic features.
Data Management and Diagnostics
The Multilin Capacitor Bank Controller provides advanced disturbance diagnostic features that significantly reduce the time and costs associated with troubleshooting power system events and reconstruction. Recording functions include enhanced diagnostics with a 10 channel RMS recorder Data Logger.
Statistics & Counters
The Multilin Capacitor Bank Controller provides counters which records key operational parameters to aid in enabling preventative maintenance programs. The Multilin Capacitor Bank Controller includes many counters & statistical values.
Advanced Device Health Diagnostics
Comprehensive device health diagnostic tests are performed by the Multilin Capacitor Bank Controller during startup and continuously at runtime to test its own major functions and critical hardware. These diagnostic tests monitor for conditions that could impact the Multilin Capacitor Bank Controller’s performance, evaluates the potential impact and criticality of this condition and presents the device status to operators, via SCADA and/or through the front panel display.
Communications
The Multilin Capacitor Bank Controller utilizes industry standard, communications technologies making it one of easiest and most flexible controllers to use and integrate into new and existing SCADA or DMS infrastructures. Supported communication protocols include:
- DNP 3.0
- Modbus RTU (RS485)
Multiple communication ports and protocols allow for remote control and easy access to device and system information. All communication ports are capable of simultaneous communications. The Multilin Capacitor Bank Controller can also communicate to Volt/VAR or SCADA systems via wireless communications media. The supported wireless media includes:
- Wireless Radio (MDS or customer specific)
- GSM/GPRS
- Pre-wired for future radio
Front Panel
Front Panel Quick Keys
Front Penel quick keys provides direct access to key individual setting parameters
Key Features
4-Level device security to maintain authorized access only
Simplified device configuration software tool and industry leading suite of software tools to manage and maintain Multilin devices.
Security
The Multilin Capacitor Bank Controller and associated software tools provide a suite of security features that ensure only approved personnel can make changes to the configuration of the system or execute commands. These functions enable a utility to meet NERC/CIP requirements.
Password Security
The Multilin Capacitor Bank Controller offers multiple levels of password security to limit access control based on settings or command levels. There are four levels of password security provided:
- Local Settings Access
- Local Control Access
- Remote Settings Access
- Remote Control Access
Local Access refers to users making changes using the front USB serial port and the HMI. Remote Access refers to users making changes using the rear RS485 port.
EnerVista™ Software
The EnerVista™ Suite is an industry-leading set of software programs that simplifies every aspect of using the Multilin Capacitor Bank Controller The EnerVista™ suite provides all the tools to monitor the status of the protected asset, maintain the controller, and integrate information measured by the DGCC into SCADA or the DMS monitoring systems. The ability to easily view sequence of events is an integral part of the setup software, as postmortem event analysis is critical to proper system operation.
Learn More
Recommended Products & services
DFP200 Digital Feeder Protection (Discontinued)
The DFP200 is a digital relay system that provides distribution feeder protection, control, metering, and monitoring. It uses waveform sampling of the current and voltage inputs at 32 times per cycle. Incorporating multiple functions in one package eliminates the need for expensive discrete components.
DFP200 Digital Feeder Protection (Discontinued)
The DFP200 is a digital relay system that provides distribution feeder protection, control, metering, and monitoring. It uses waveform sampling of the current and voltage inputs at 32 times per cycle. Incorporating multiple functions in one package eliminates the need for expensive discrete components.
Recommended Products & services
DFP100 Digital Feeder Relay (Discontinued)
The DFP100 is a digital protection, control, metering, and monitoring system. It uses waveform sampling of the current and voltage inputs together with appropriate algorithms to provide distribution feeder protection. The DFP100 incorporates the protection, control, metering, and both local and remote human interfaces in one assembly. This eliminates the need for expensive discrete components.
DFP100 Digital Feeder Relay (Discontinued)
The DFP100 is a digital protection, control, metering, and monitoring system. It uses waveform sampling of the current and voltage inputs together with appropriate algorithms to provide distribution feeder protection. The DFP100 incorporates the protection, control, metering, and both local and remote human interfaces in one assembly. This eliminates the need for expensive discrete components.
Recommended Products & services
DFF Digital Frequency Relay - Legacy
Manufacturing for this product has been discontinued. As an alternative, please refer to the F60, G60
DFF Digital Frequency Relay - Legacy
Manufacturing for this product has been discontinued. As an alternative, please refer to the F60, G60
Recommended Products & services
DDS Digital Distribution System - Legacy
Manufacturing for DDS has been discontinued. Please see individual product pages for more information.
The DDS family of devices provide economical protection, control, metering and monitoring functionality to electrical utilities and industrial customers.
DDS Digital Distribution System - Legacy
Manufacturing for DDS has been discontinued. Please see individual product pages for more information.
The DDS family of devices provide economical protection, control, metering and monitoring functionality to electrical utilities and industrial customers.